MSO6104HDP | 1 GHz 4-Channel 12-Bit Mixed Signal Oscilloscope
Overview
The MSO6104HDP is a 1 GHz, 4-channel mixed signal oscilloscope built on a native 12-bit ADC, with up to 10 GSa/s real-time sampling, up to 1 Gpts of memory and a 50 Ξ© rise time of β€ 350 ps (typical). Waveform capture runs at 800,000 wfms/s, or 2,000,000 wfms/s in sequence mode, on a 12.1-inch 1280 Γ 800 capacitive touchscreen.
It shares its chassis, acquisition system and analysis options with the 2 GHz MSO6204HDP, so a bench can start at 1 GHz and move to 2 GHz later with the MSO6000HDP-BW1GT2G license (Optional) instead of a new instrument. The 1 MΞ© path is specified to 500 MHz on both models.
Sixteen digital channels, a digital voltmeter, a 7-digit frequency counter and a 10 Mpts FFT are built in. Protocol decoding covers RS232/422/485/UART, IΒ²C, SPI and IΒ³C as standard, with automotive, audio, MIL-STD-1553B, ARINC 429, Manchester and 1-Wire decoders as options. Backed by the 3+2 warranty.
Key Features
- 1 GHz at 50 Ξ©, 500 MHz at 1 MΞ© β rise time β€ 350 ps (typical) on the 50 Ξ© path; four analog channels plus external trigger.
- Native 12-bit ADC β 4,096 vertical levels, 16 times an 8-bit design, with ERES extending resolution up to 16 bits.
- Up to 10 GSa/s and 1 Gpts β 10 GSa/s in interleaved mode, 5 GSa/s non-interleaved; 500 Mpts per channel with all four channels on, 1 Gpts on a single channel.
- 800,000 wfms/s with Ultra Phosphor 3.0 and 256 intensity levels; 2,000,000 wfms/s in sequence mode, with up to 400,000 frames recorded in hardware.
- 16 digital channels at 1.25 GSa/s, enabled by the UT-M15 logic probe (sold separately), for correlated analog and digital debug.
- Protocol trigger and decode β RS232/422/485/UART, IΒ²C, SPI and IΒ³C included; CAN, CAN-FD, CAN-XL, LIN, FlexRay, SENT, audio, MIL-STD-1553B, ARINC 429, Manchester and 1-Wire (Optional).
- Analysis options β power analysis (12 types), timing analysis, jitter and eye diagram, USB 2.0 and 100/1000 Ethernet compliance, and a dual-channel 50 MHz generator with Bode plot (all Optional).
- 56 automated measurements, 27 on screen at once, each with histogram and trend statistics; 10 Mpts FFT with waterfall; 4-digit DVM and 7-digit counter.
- 12.1-inch 1280 Γ 800 touchscreen, fully laminated, with gesture control plus physical keys, knobs, mouse and keyboard.
- Connectivity β three USB 3.0 host ports, USB Type-C 3.0, gigabit LAN, HDMI, 10 MHz reference in/out, SCPI and a built-in web server.
Detailed Features
1 GHz Today, 2 GHz by License
The MSO6104HDP uses the same 12-bit acquisition system as the 2 GHz model. Its 4,096 vertical levels β 16 times an 8-bit front end β keep small ripple and settling detail visible at 1 GHz, and ERES extends resolution to 16 bits where bandwidth can be traded for it.
When a project needs more bandwidth, the MSO6000HDP-BW1GT2G license (Optional) raises the 50 Ξ© bandwidth to 2 GHz on the instrument already on the bench.
The same signal on an 8-bit (left) and 12-bit (right) acquisition.
All-in-One Measurement Platform
The MSO6000HDP combines an oscilloscope, 16-channel logic analyzer, spectrum analysis, digital voltmeter, 7-digit frequency counter and protocol analyzer as standard, with a dual-channel function/arbitrary waveform generator, Bode plot analyzer, power analyzer, timing analyzer and jitter tools as options, all on the same screen and timebase.
Options install by license file from a USB drive, so capability can be added to an instrument already on the bench.
Standard and optional functions on one platform; optional functions require the matching license.
800,000 Waveforms per Second
Ultra Phosphor 3.0 processes acquisitions through a parallel graphics-mapping pipeline at 800,000 wfms/s, with 256 intensity levels so frequent and rare events read differently on screen. In sequence mode the capture rate rises to 2,000,000 wfms/s, with a minimum trigger interval under 500 ns.
Hardware waveform recording keeps up to 400,000 frames for frame-by-frame or continuous playback, with measurements and math available on the recorded data, and the frames can be exported to USB storage.
Intensity grading shows how often each trace occurs.
Deep Memory with Search and Navigation
Memory depth reaches 500 Mpts per channel with all four channels enabled and 1 Gpts on a single channel, enough to hold long bursts at a high sample rate. Search marks every edge, pulse width, runt, timeout, setup-and-hold or pattern event that meets your criteria across the full record.
Results appear as an event list; select an entry to jump to it, or step through events, time positions and markers with the navigation controls.
Search marks each matching event across the record.
Protocol Trigger and Decode
RS232/422/485/UART, IΒ²C, SPI and IΒ³C trigger and decode are standard. Options add CAN, CAN-FD, CAN-XL, LIN, FlexRay and SENT for automotive work, audio buses (IΒ²S, left-justified, right-justified, TDM), MIL-STD-1553B and ARINC 429 for avionics buses, Manchester and 1-Wire β 15 protocols in all.
Up to four buses decode at once, from analog or digital channels, and a parallel bus of up to 18 bits can combine both. Decoding works while stopped or recording, with an event list, search and CSV, HTML or PDF export.
Decoded bus traffic with the event table.
Mixed Signal Debugging
Sixteen digital channels are built into every MSO6000HDP and are enabled by the UT-M15 logic analyzer probe (sold separately). They sample at 1.25 GSa/s with up to 500 Mpts of memory, detect pulses down to 5 ns and accept thresholds from TTL to LVDS or a custom level.
Digital channels trigger, decode and measure alongside the analog channels, so a firmware state change can be lined up against the analog event it caused.
Digital channels grouped into a bus.
Power Analysis (Optional)
The MSO6000HDP-PWR option adds twelve power measurements: power quality, harmonics, inrush current, RDS(on), switching loss, slew rate, safe operating area, modulation, ripple, turn-on/turn-off time, transient response and efficiency.
Connect voltage and current probes to the stage under test, select the analysis, assign the channels and read the results. With the MSO6000HDP-GEN option, the Bode plot function adds control-loop and PSRR measurement from 50 Hz to 50 MHz.
Power analysis results across four channels.
Jitter and Eye Diagram (Optional)
The MSO6000HDP-JITTER option measures TIE, total jitter at a set BER, random, deterministic, periodic, data-dependent and duty-cycle-distortion jitter, with TIE histogram, trend and spectrum views and a bathtub curve.
Hardware-accelerated eye diagrams report eye height, eye width, amplitude, Q-factor and crossing ratio, with clock recovery by fixed frequency or first- or second-order PLL.
Eye diagram, bathtub curve, TIE histogram and TIE trend.
Compliance Testing (Optional)
Compliance options run automated USB 2.0 (MSO6000HDP-CTSUSB20), 100BASE-TX (MSO6000HDP-CTS100) and 1000BASE-T (MSO6000HDP-CTS1000) Ethernet tests with the matching test fixtures. The software shows the connection to the device under test, configures the oscilloscope for each test item and generates a report with results, pass/fail status, margins and waveform images.
Single or multiple test items can be run, and custom limits can be applied alongside the standard ones.
Timing Analysis (Optional)
The MSO6000HDP-TIMING option checks bus timing on IΒ²C, SPI, CAN, IΒ²S, UART and LIN, plus reset and switch sequences: pulse width, amplitude, edge timing, rise time, setup and hold.
Each parameter is compared against its limit and the results export as a report.
IΒ²C timing analysis with pass/fail per parameter.
Measurements and Statistics
56 automated measurements cover voltage, time, area, burst, delay and phase. 27 can be on screen at once, and each one can show statistics as a histogram or a trend chart, so drift and outliers are visible without exporting data.
A measurement snapshot shows 39 parameters for one channel, and precision mode measures across the full memory in hardware rather than the screen record.
Measurement statistics with a trend plot.
Area Trigger, Mask Test and Histograms
Draw up to two rectangles on the touchscreen and the area trigger keeps only waveforms that cross, or avoid, those zones, which isolates an intermittent glitch without building a complex trigger. The standard trigger set adds edge, pulse width, video, slope, runt, window, delay, timeout, duration, setup and hold, Nth edge and pattern.
Hardware-accelerated mask testing runs pass/fail against a template in seconds and can stop, sound the buzzer or save a screenshot on failure. Vertical and horizontal histograms quantify noise and jitter distributions.
Mask test with pass/fail counts.
Spectrum Analysis
The FFT runs up to 10 Mpts on all four channels, with Hanning, Hamming, rectangular, Blackman and flat-top windows, a waterfall view, normal, average, max-hold and min-hold traces and automatic, manual or threshold markers.
Start, stop, center and span are set directly in frequency, so harmonics, switching noise and EMI sources can be examined without leaving the time-domain view.
Time and frequency domain on one screen.
Touchscreen, Keys and Remote Control
The 12.1-inch 1280 Γ 800 capacitive touchscreen is fully laminated and supports tap, drag, pinch and box-zoom gestures, while dedicated keys and knobs stay on the front panel. A USB mouse and keyboard also work, and autoset settles unknown signals within 1.5 seconds across all channels.
For automation, the instrument accepts SCPI over LAN or USB, runs a built-in web server for browser control from a PC or phone, and works with the free UNI-T Instrument Manager. Firmware updates install from a USB drive or online.
Browser-based control from a PC or mobile device.
Applications
R&D and High-Speed Digital Design
- Characterise clocks and serial links on the 50 Ξ© path, with jitter and eye-diagram analysis on the same instrument (Optional).
- Run USB 2.0 and 100/1000 Ethernet compliance tests before a board goes to a test house (Optional).
- Bring up embedded designs with IΒ²C, SPI, IΒ³C and UART decode and 16 digital channels lined up against the analog signals.
Power Electronics
- Measure switching loss, RDS(on), SOA and efficiency on converters and motor drives with the power analysis option.
- Check control-loop stability and PSRR with the Bode plot function (requires the generator option).
- See rail ripple and gate-drive detail at 12 bits without switching to an averaging mode.
Automotive and Embedded Systems
- Decode CAN, CAN-FD, CAN-XL, LIN, FlexRay and SENT traffic and verify bus timing (Optional).
- Decode MIL-STD-1553B and ARINC 429 avionics buses (Optional).
- Capture intermittent faults with sequence mode, area trigger and 400,000-frame hardware recording.
Test Labs and Production
- Automate measurements over SCPI, LAN and the built-in web server.
- Run hardware mask tests with pass/fail output on the AUX port.
- Export decoded events, measurements and reports as CSV, HTML or PDF.
In the Box
- Power cord
- 4 Γ UT-P07A 500 MHz high-impedance passive probe (two sets of two)
- UT-L45 BNC-to-BNC straight-through cable
- UT-L02A BNC to red/black alligator clip cable
- USB 3.0 data cable, USB-A to USB-C, 1 m
- Certificate of calibration
- Multi-language safety precautions and English quick guide
Instrument dimensions 365 Γ 264 Γ 115 mm (W Γ H Γ D), 6.0 kg.
Recommended Add-Ons
- UT-M15 β 16-channel logic analyzer probe; enables the digital channels.
- UT-PA2000 β 2 GHz active single-ended probe.
- UT-PD2500 β 2.5 GHz active differential probe.
- UT-PR2060 β 1 GHz low-noise power rail probe.
- UT-P43 / UT-P44 β 25 MHz / 50 MHz current probes for power analysis.
- UT-P31 β 100 MHz high-voltage differential probe.
- UT-ISOT β isolation transformer.
- MSO6000HDP-BW1GT2G β bandwidth upgrade from 1 GHz to 2 GHz (Optional).
- MSO6000HDP-BND β all optional serial bus trigger and decode in one license (Optional).
- MSO6000HDP-GEN β dual-channel 50 MHz function/arbitrary waveform generator with Bode plot (Optional).
- MSO6000HDP-PWR, -TIMING, -JITTER β power, timing, and jitter and eye-diagram analysis (Optional).
Frequently Asked Questions
What is the difference between the MSO6104HDP and the MSO6204HDP?
Bandwidth on the 50 Ξ© path: 1 GHz (β€ 350 ps rise time) on the MSO6104HDP and 2 GHz (β€ 210 ps) on the MSO6204HDP. Both are specified to 500 MHz on the 1 MΞ© path and share the chassis, 12-bit acquisition, memory, display and options. The MSO6104HDP can be upgraded to 2 GHz with the MSO6000HDP-BW1GT2G license (Optional).
Do I get 10 GSa/s on every channel?
No. 10 GSa/s is the interleaved-mode rate; in non-interleaved mode the rate is 5 GSa/s. Memory is 500 Mpts per channel with all four channels enabled and 1 Gpts on a single channel.
Are the 16 digital channels included?
The 16-channel logic analyzer hardware is built in. It is enabled by connecting the UT-M15 logic analyzer probe, which is sold separately.
Is the waveform generator included?
The dual-channel 50 MHz function/arbitrary waveform generator is the MSO6000HDP-GEN option (Optional). The same option enables the Bode plot function for loop and PSRR measurements.
Which protocol decoders are standard?
RS232/422/485/UART, IΒ²C, SPI and IΒ³C are included. CAN, CAN-FD, CAN-XL, LIN, FlexRay, SENT, audio, MIL-STD-1553B, ARINC 429, Manchester and 1-Wire are options, individually or as the MSO6000HDP-BND bundle.
Can the MSO6104HDP be upgraded later?
Yes. Bandwidth moves from 1 GHz to 2 GHz with the MSO6000HDP-BW1GT2G license, and analysis and decode options install by license file from a USB drive (all Optional).
| Analog Bandwidth | 1GHz | ||||
|---|---|---|---|---|---|
| Channels | 4Ch+16D (opt) | ||||
| Sample Rate | 10GSa/s | ||||
| Memory Depth |
|
||||
| Vertical Resolution | 12 bits | ||||
| Built-in Signal Generator | Optional | ||||
| Digital Channels | Optional | ||||
| Touch Screen | ✓ | ||||
| Instrument Type | HD Mixed Signal Oscilloscope |
Features
- Frequency Counter
- Digital Voltmeter
Full specifications (26)
| Details | |||||
|---|---|---|---|---|---|
| Waveform Capture Rate |
|
||||
| Input Impedance | 1 MΞ© | 50 Ξ© | ||||
| Vertical Scale (1 MΞ©) | 500ΞΌV/div to 10V/div | ||||
| Vertical Scale (50 Ξ©) | 500ΞΌV/div to 1V/div | ||||
| Automated Measurements | 56 | ||||
| Bus Protocols (Standard) | RS232|UART|RS422|RS485|I2C|SPI|I3C | ||||
| Bus Protocols (Optional) | CAN|LIN|CAN-FD|CAN-XL|FlexRay|SENT|Audio|MIL-STD-1553B|ARINC429|Manchester|1-WIRE | ||||
| Protocol Decoders | 15 | ||||
| Measurement Parameters | 56 | ||||
| FFT Points | 10Mpts | ||||
| Features | |||||
| Frequency Counter Bits | 7-digit | ||||
| Rise Time | β€0.35 ns | ||||
| Power Analysis | 12 | ||||
| Modulation Types | AM|FM|ASK|FSK | ||||
| DVM Resolution | 4-digit | ||||
| AWG Channels | 2 | ||||
| AWG Frequency | 50 MHz | ||||
| Arb Memory Depth | 16kpts | ||||
| Standard Waveforms | Sine|Square|Ramp|Pulse|Noise|DC|Arbitrary | ||||
| General Information | |||||
| Display Size | 12.1in | ||||
| Interface | USB Host x3|USB Type-C|LAN|HDMI|AUX Out|EXT Trig|10MHz Ref In/Out|Gen Out x 2 | ||||
| Operating Temperature | 0 Β°C to +50 Β°C | ||||
| Dimensions (WΓHΓD) | 365 Γ 264 Γ 115 mm | ||||
| Weight | 6.0 kg | ||||
| Warranty | 3+2 years | ||||
| Certifications | CE|cETLus | ||||
Data Sheets and Manuals
Authentic UNI-T accessories are an affordable way to extend the functionality of your instrument.
MSO6000HDP Options 21
Need to add specific functionality to your UNI-T instrument? Here are our options for specific applications and measurement types. Have a question? Contact us at 888-668-UniT (8648).

MSO6000HDP-1WIRE Sensor Serial Bus Trigger and Decode Option (1-Wire)
$449.00
MSO6000HDP-ARINC429 Aerospace Serial Bus Trigger and Analysis Option (ARINC 429)
$449.00
MSO6000HDP-AUDIO Audio Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)
$449.00
MSO6000HDP-AUTO Automotive Serial Bus Trigger and Decode Option (CAN, CAN-FD, CAN-XL, LIN, FlexRay, SENT)
$880.00
MSO6000HDP-BND All Serial Bus Trigger and Decode Option (CAN, CAN-FD, CAN-XL, LIN, FlexRay, SENT, Audio, MIL-STD-1553, ARINC 429, Manchester, 1-Wire)
$2,199.00
MSO6000HDP-BW1GT2G 1 GHz to 2 GHz Bandwidth Upgrade Option
$5,999.00
MSO6000HDP-CAN Automotive Serial Bus Trigger and Analysis Option (CAN)
$449.00
MSO6000HDP-CANFD Automotive Serial Bus Trigger and Analysis Option (CAN-FD)
$449.00
MSO6000HDP-CANXL Automotive Serial Bus Trigger and Decode Option (CAN-XL)
$449.00
MSO6000HDP-CTS100 100BASE-TX Ethernet Compliance Analysis Option
$888.00
MSO6000HDP-CTS1000 1000BASE-T Ethernet Compliance Analysis Option
$1,480.00
MSO6000HDP-CTSUSB20 USB 2.0 Compliance Analysis Option
$1,480.00
MSO6000HDP-FLEX Automotive Serial Bus Trigger and Analysis Option (FlexRay)
$449.00
MSO6000HDP-GEN Dual-Channel Arbitrary Waveform Generator Option (including Gen and Bode plot)
$439.00
MSO6000HDP-JITTER Jitter and Eye Diagram Analysis Option
$1,480.00
MSO6000HDP-LIN Automotive Serial Bus Trigger and Analysis Option (LIN)
$449.00
MSO6000HDP-MANCH Serial Bus Trigger and Analysis Option (Manchester)
$449.00
MSO6000HDP-MIL1553 Aerospace Serial Bus Trigger and Analysis Option (MIL-STD-1553)
$449.00
MSO6000HDP-PWR Power Analysis Option
$1,480.00
MSO6000HDP-SENT Automotive Sensor Bus Trigger and Analysis Option (SENT)
$449.00
MSO6000HDP-TIMING Timing Analysis Option (including I2C, SPI, CAN, I2S, Reset, Switch, UART, LIN)
$888.00Passive Probes 11

UT-P01 25 MHz 10:1 General Purpose Oscilloscope Probe
$15.99
UT-P03 60 MHz 10:1 General Purpose Oscilloscope Probe
$18.99
UT-P04 100 MHz 10:1 General Purpose Oscilloscope Probe
$15.99
UT-P05 200 MHz 10:1 General Purpose Oscilloscope Probe
$20.99
UT-P06 300 MHz 10:1 General Purpose Oscilloscope Probe
$37.99
UT-P07A 500 MHz 10:1 General Purpose Oscilloscope Probe
$51.99UT-P07B 500 MHz 10:1 General Purpose Oscilloscope Probe
$119.00
UT-P08A 350 MHz 10:1 General Purpose Oscilloscope Probe
$51.99
UT-P20 250 MHz 100:1 High Voltage Oscilloscope Probe
$56.99
UT-P21 50 MHz 1000:1 High Voltage Oscilloscope Probe
$430.00
UT-V23 High Voltage Scope Probe
$25.00Current Probes 6

UT-P40 DC-100 kHz 60A AC/DC Current Probe
$452.00
UT-P41 DC-100 kHz 100A AC/DC Current Probe
$595.00
UT-P4150 12 MHz High-Frequency DC/AC Current Probe
$2,529.00
UT-P42 150 kHz 200A AC/DC Current Probe
$459.00
UT-P43 DC-25 MHz 20A 100mV/A Current Probe
$956.00
UT-P44 DC-50 MHz 40A 50mV/A Current Probe
$1,695.00Differential Probes 6

UT-P30 100 MHz 10:1/100:1 Differential Oscilloscope Probe
$399.00
UT-P31 100 MHz 100:1/1000:1 Differential Oscilloscope Probe
$699.00
UT-P32 50 MHz 100:1/1000:1 Differential Oscilloscope Probe
$860.00
UT-P33 120 MHz 100:1/1000:1 Differential Oscilloscope Probe
$1,465.00
UT-P35 50 MHz 50:1/500:1 Differential Oscilloscope Probe
$395.00