UT-P4500 5 MHz 500 A High-Frequency AC/DC Current Probe
Overview
The UT-P4500 is a 5 MHz Hall-effect current probe for DC and AC currents up to 500 Arms continuous and 750 A peak. Its 20 mm jaw closes around heavy cables and bus bars in inverters, motor drives and battery systems, and it is insulated to 300 V CAT III.
Two ranges are selected on the probe: 75 A at 0.1 V/A and 500 A at 0.01 V/A, each accurate to ±1% (DC, 45–66 Hz).
Key Features
- DC to 5 MHz, ≤70 ns rise time — for high-current switching and inrush.
- 500 Arms continuous, 750 A peak — maximum ratings.
- 75 A and 500 A ranges — 0.1 V/A and 0.01 V/A; 10 mA and 100 mA resolution.
- ±1% amplitude accuracy — ±1% ±10 mA (75 A range) and ±1% ±100 mA (500 A range).
- 20 mm jaw, 300 V CAT III — for large conductors in installed equipment.
- Degauss and auto-zero — one button demagnetizes the core and zeroes the output.
- Overload alarm — LED and buzzer warning above range.
UT-P4500 Details
Setting up a measurement
Set the oscilloscope channel to 1 MΩ input and DC coupling, power the probe from its 12 V adapter, select the range and, with the jaw empty and locked, press degauss/auto-zero. Clamp the conductor in the centre of the jaw with the arrow in the direction of current flow, and allow about 30 minutes of warm-up for stable offset.
Three-phase power
UNI-T's three-phase power analysis uses an 8-channel UPO6000LP oscilloscope with three high-voltage differential probes and three current probes, one per phase.
Applications
- Inverters and motor drives — phase and DC-bus current at high power.
- EV and energy storage — battery, charger and PV inverter currents.
- Industrial power — inrush and load current on heavy conductors.
Compatibility
Works with oscilloscopes that have a 1 MΩ BNC input. For three-phase analysis, the 8-channel UPO6108LP with the UPO6000LP-PWR option takes three current probes and three high-voltage differential probes such as the UT-P31. For faster, lower-current work see the UT-P4150 (12 MHz, 150 A).
Frequently Asked Questions
What oscilloscope input setting does it need?
1 MΩ and DC coupling. A 50 Ω input gives incorrect readings.
What is the largest conductor it accepts?
Up to 20 mm in diameter.
Can it measure continuously at 500 A?
Yes, 500 Arms is the continuous rating. The maximum continuous input falls at higher frequencies, and a built-in safety function blocks the output if the sensor overheats.
| Analog Bandwidth | 5MHz |
|---|---|
| Instrument Type | Current Probe |
Full specifications (13)
| Details | |||||
|---|---|---|---|---|---|
| CAT Rating | 300V CAT III | ||||
| Connector Type | BNC | ||||
| Cable Length | 1.5m | ||||
| Rise Time | ≤70ns | ||||
| Features | |||||
| Max Current | 500Arms continuous, 750Apk | ||||
| Max Conductor Size | 20mm | ||||
| Dc Accuracy |
|
||||
| Storage Temperature | -10°C to 50°C | ||||
| Output Sensitivity |
|
||||
| General Information | |||||
| Operating Temperature | 0°C to 40°C | ||||
| Operating Humidity | ≤80% RH | ||||
| Weight | 525g | ||||
| Warranty | 1 year | ||||