Skip to product information
1 of 7

UPO7204L

Lab-Grade 2 GHz 4Ch Eight-in-One Rack-Mount Oscilloscope

Regular price $13,999.00
Sale Contact Us For Lead Time

2 in stock

2 GHz 4-channel digital storage oscilloscope with 10 GSa/s sample rate, 2,000,000 wfms/s capture rate. Versatile eight-in-one rack-mount platform for embedded developers.

View full details

UPO7204L | Lab-Grade 2 GHz 4-Channel Eight-in-One Rack-Mount Oscilloscope

Overview

The UPO7204L is a lab-grade 2 GHz, four-channel digital storage oscilloscope in a 1U headless rack-mount form factor, engineered for high-density ATE rack integration, parallel high-channel-count semiconductor parametric test, and aerospace/automotive validation environments. The full 2 GHz analog bandwidth and 10 GSa/s sample rate are available in single-channel mode at 50 Ω; four-channel mode runs at 1 GHz analog bandwidth and 2.5 GSa/s. With 1 Gpts of acquisition memory in single-channel mode (250 Mpts at full four-channel), UltraAcq® waveform mapping at ≥600,000 wfms/s standard (2,000,000 wfms/s in Sequence mode), and external display via HDMI plus full WebServer browser-based remote control, the UPO7204L is an eight-in-one bench platform consolidating oscilloscope, spectrum analyzer, DVM, frequency counter, AWG, multi-bus protocol analyzer, power analyzer, and jitter analyzer with eye diagram (some functions require optional license unlocks — see Detailed Features below).

For high-speed digital signal-integrity work at 2 GHz analog bandwidth in ATE rack environments, serial-link compliance in the USB 3.0 / PCIe Gen 1-2 region, MIPI characterization, jitter analysis on data rates above ~1 Gbps, and parallel high-channel-count test architectures where benchtop scopes hit channel-count and rack-density ceilings, the UPO7204L is the top SKU in the UPO7000L line. Calculated rise time of 175 ps resolves leading-edge content on the fastest commercial silicon. Selectable 50 Ω / 1 MΩ inputs (1 MΩ caps at 500 MHz) bring RF-grade signal-chain options to the same instrument. Multi-machine synchronization up to 128 units / 512 channels enables parallel test architectures benchtop scopes cannot match.

Key Features

  • 2 GHz Bandwidth, 4 Analog Channels + 1 EXT — Lab-grade four-channel acquisition with 10 GSa/s peak sample rate (single-channel), 2.5 GSa/s at full four-channel, and calculated rise time of 175 ps. The full 2 GHz analog bandwidth is available in single-channel mode at 50 Ω (typical for high-bandwidth signal-integrity work with the UT-PA2000 active probe); four-channel mode caps at 1 GHz, sufficient for the bulk of ATE-rack and R&D validation work. Selectable 50 Ω / 1 MΩ inputs (1 MΩ caps at 500 MHz) support both RF-grade and general-purpose probing on the same channel front end.
  • 10 GSa/s Sample Rate, 1 Gpts Memory, UltraAcq® Acquisition — Peak 10 GSa/s (single-ch) / 5 GSa/s (dual) / 2.5 GSa/s (full four-ch) with corresponding 1 Gpts / 500 Mpts / 250 Mpts memory depth, all standard configuration. UltraAcq® multi-body cross-mapping with sub-1 µs dead time delivers ≥600,000 wfms/s standard and 2,000,000 wfms/s in Sequence mode.
  • High Resolution Mode and FPGA-Resident ERes — 8-bit native ADC with two paths to higher effective vertical resolution: HR mode (12 effective bits via averaging, full sample rate retained) and ERes (acquisition menu, FPGA-resident FIR filter, +3 bits on band-limited signals). UPO7000L is the only UNI-T scope where ERes is acquisition-domain rather than Math-menu.
  • 1U Headless Rack-Mount Form Factor — 214 mm × 43 mm × 500 mm, <3.5 kg; two units mount side-by-side in one full-width 1U slot. HDMI external display; WebServer browser-based remote control over LAN.
  • Multi-Machine Synchronization — Up to 128 Units / 512 Channels — Synchronized data acquisition across up to 128 instruments expandable to 512 channels with 200 ps RMS inter-instrument trigger jitter. UNI-T provides synchronizer hardware as part of multi-channel integrated solutions for parallel-test ATE racks.
  • Eight-in-One Platform — Oscilloscope, enhanced-FFT spectrum analyzer, 4-digit DVM, 8-digit hardware frequency counter, 60 MHz single-channel AWG (optional UPO7000L-AWG), 11-protocol multi-bus serial-bus analyzer, six-measurement power analyzer (optional UPO7000L-PWR), and jitter analyzer with eye diagram (optional UPO7000L-JITTER).
  • 11-Protocol Decode Set — Standard: RS-232/422/485/UART, I²C, SPI, CAN, LIN. Optional: CAN-FD, FlexRay, SENT, AudioBus (I²S/LJ/RJ/TDM), MIL-STD-1553/ARINC 429.
  • Windows 10 Platform with WebServer — Intel Core i5-7200U 2.5 GHz, 8 GB RAM, 128 GB SSD; on-instrument MATLAB/Python post-processing; built-in WebServer for browser-based remote control over LAN with PC and smartphone layouts.
  • Optional Jitter Analysis & Eye DiagramUPO7000L-JITTER: eye diagram with multiple clock-recovery methods plus full TJ/RJ/DJ/PJ/DDJ/DCD jitter decomposition for serial-link compliance work above ~1 Gbps.
  • Standard Mask & Limit Testing, SCPI & WebServer Remote Control — Production-line spot-check and pass/fail evidence reporting; full SCPI command set (USBTMC), dual LAN (10/100/1000) for redundant ATE network topologies, browser-based remote control with no driver installation.

Detailed Features

UPO7000L eight integrated instruments
Eight instruments integrated in 1U: scope, spectrum analyzer, DVM, frequency counter, AWG, protocol analyzer, power analyzer, jitter analyzer.

Eight Instruments in One Rack-Mount Platform

The UPO7000L integrates eight instrument functions in one 1U headless rack-mount unit. Standard configuration includes the digital storage oscilloscope, enhanced-FFT spectrum analyzer, 4-digit digital voltmeter, 8-digit hardware frequency counter, and the standard portion of the 11-protocol multi-bus analyzer (RS-232/422/485/UART, I²C, SPI, CAN, LIN). Function-unlock options enable the remaining four instruments: 60 MHz single-channel function/arbitrary waveform generator (UPO7000L-AWG, 16-bit, 625 MSa/s), advanced jitter and eye diagram (UPO7000L-JITTER), and six-measurement power analysis (UPO7000L-PWR). Optional protocol licenses extend decode to CAN-FD, FlexRay, SENT, AudioBus, and aerospace MIL-STD-1553/ARINC 429 — or bundle them with UPO7000L-BND. For independent ATE integrators and design consultancies running parallel rack-based test at the high-bandwidth tier, the integration condenses what would otherwise be seven or eight separate instruments per rack slot into one 1U headless instrument under WebServer remote control.

UltraAcq® Acquisition Engine — ≥600K wfms/s Standard, 2M Sequence

UltraAcq® is UNI-T’s flagship acquisition architecture: multi-body cross-mapping with sub-1 µs dead time and waveform-mapping rates of ≥600,000 wfms/s standard, 2,000,000 wfms/s in Sequence mode. Compared to traditional 200,000 wfms/s scopes, the UPO7000L captures more than one million 200 ps fast-edge events per second — the difference between catching an intermittent fault and missing it. Information-entropy-based intelligent detection further isolates abnormal signals in long-duration captures.

UPO7000L UltraAcq high-speed acquisition
UltraAcq® delivers ≥600,000 wfms/s standard; 2,000,000 wfms/s in Sequence mode with sub-1 µs dead time.
UPO7000L 1U rack-mount dimensions
1U half-width 214 × 43 × 500 mm; <3.5 kg; engineered for ATE rack integration.

1U Headless Rack-Mount Form Factor

The UPO7000L is engineered for 1U rack-mount integration: 214 mm × 43 mm × 500 mm, <3.5 kg, no built-in display. Two UPO7000L units mount side-by-side in one full-width rack slot. The half-width 1U form factor allows two units to share one full-width rack slot, freeing rack density for ATE installations where benchtop scopes structurally cannot integrate. HDMI output drives an external monitor when local visual debug is required; WebServer remote control over LAN handles routine measurement and configuration without operator presence at the rack.

Windows 10 Platform with WebServer Remote Control

The UPO7000L runs Windows 10 IoT Ent LTSC 64-bit on an Intel Core i5-7200U at 2.5 GHz with 8 GB RAM and a 128 GB SSD — a real general-purpose computing platform under the instrument, not an embedded shell. The built-in WebServer provides browser-based remote control from PC or smartphone via IP address, supporting two layout styles (PC-grade and smartphone-grade) without driver installation. Full SCPI command set (USBTMC) over USB Device or LAN supports script-driven automated test sequences for ATE integration. On-instrument MATLAB and Python pipelines handle post-processing without round-tripping captures to a host computer.

Deep Memory — Up to 1 Gpts Standard

The 1 Gpts memory depth at single-channel mode is the deepest acquisition window standard-configuration in the UPO7000L line — capturing tens of thousands of waveforms in a single acquisition for post-event analysis on high-speed serial-link compliance work, multi-cycle GaN/SiC switching transients, and long-duration jitter characterization. At dual-channel mode, memory remains 500 Mpts; full four-channel runs at 250 Mpts. For ATE integrators running customer-design validation across multi-cycle transient and long-record acquisition work, the deep memory budget makes pass/fail evidence reports comprehensive on the first capture — meaningful test-time savings on rework cycles.

Vertical Resolution — 8-Bit Native with HR Mode and FPGA-Resident ERes

The UPO7204L delivers up to 2 GHz of bandwidth at 10 GSa/s on an 8-bit acquisition front end, with two distinct paths to higher effective vertical resolution — both available without leaving the acquisition menu. High Resolution mode applies single-acquisition averaging to reach up to 12 effective bits at the full sample rate. Enhanced Resolution (ERes) on the UPO7000L is FPGA-resident in the acquisition menu (unlike the MSO7000X, where ERes is a Math-menu post-acquisition operation) — it processes waveforms directly in hardware via FIR filtering for up to 3 additional bits on band-limited signals (each 0.5-bit improvement halves usable sample rate), so the enhancement is available on single-shot, repetitive, and aperiodic signals alike. This is the highest-resolution path available in UNI-T’s 1U rackmount form factor; native 12-bit acquisition is not currently offered in rackmount.

Multi-Machine Synchronization — Up to 128 Units / 512 Channels

The UPO7204L supports synchronized data acquisition across up to 128 instruments expandable to 512 channels — the architectural foundation for parallel high-channel-count ATE installations that no benchtop oscilloscope can match. External trigger jitter between synchronized instruments is 200 ps RMS, maintaining time-correlation accuracy across the rack at the 2 GHz analog-bandwidth tier where signal-integrity timing precision matters most. UNI-T provides synchronizer hardware as part of multi-channel integrated solutions for aerospace, automotive, and high-density semiconductor parametric test programs. Combined with the 1U headless rack-mount form factor and WebServer remote control, this is the differentiating capability against benchtop alternatives at the 2 GHz tier.

UPO7000L multi-machine synchronization for ATE rack integration
Up to 128 synchronized instruments / 512 channels with 200 ps RMS inter-instrument jitter.

Built-In Spectrum Analyzer — Enhanced FFT to 1 Mpts

The standard enhanced-FFT spectrum analyzer covers the full oscilloscope analog bandwidth with up to 1 Mpts FFT length and multiple view types (amplitude, power, PSD, real, imaginary, phase). Two spectrum-view windows can run simultaneously across five window functions (Rectangular, Hanning, Blackman, Hamming, Flattop) — for harmonic ID, EMI pre-compliance sweeps, and modulated-signal analysis from within the same 1U rack-mount instrument as the scope acquisition.

UPO7000L 11-protocol multi-bus analyzer
11 protocols across computer, automotive, audio, aerospace, and embedded domains.

Protocol Analysis — 11 Bus Types Across Five Domains

Eleven protocols across five bus domains: computer (RS-232/422/485/UART), embedded (I²C, SPI), and automotive (CAN, LIN) standard; CAN-FD, FlexRay, SENT, AudioBus (I²S/LJ/RJ/TDM), and aerospace MIL-STD-1553/ARINC 429 optional. Trigger-and-decode integration covers frame-error, identifier-match, CRC-failure, and pattern-match conditions with inline decode display, event list, and search. The optional UPO7000L-BND upgrade suite bundles JITTER, PWR, CAN-FD, FlexRay, SENT, AUDIO, and AERO in a single package.

Jitter Analysis and Eye Diagram (Optional UPO7000L-JITTER)

For high-speed serial-link compliance and signal-integrity work, the optional UPO7000L-JITTER package adds eye-diagram analysis with multiple clock-recovery methods (fixed frequency, first-order PLL, second-order PLL, external clock), standard and user-defined eye templates, and full jitter decomposition: TIE, TJ BER, RJ, DJ, PJ, DDJ, DCD. Visualization includes TIE trend, TIE spectrogram, histogram, and bathtub curve. Eye-diagram parameters cover Eye Amplitude, Height, Width, Level 1/0, and Q-factor.

UPO7000L jitter analysis and eye diagram
Eye diagram with clock recovery; full TJ/RJ/DJ/PJ/DDJ/DCD jitter decomposition.

60 MHz Single-Channel Function/Arbitrary Waveform Generator (Optional)

The optional UPO7000L-AWG package adds a 60 MHz single-channel function/arbitrary waveform generator (16-bit, 625 MSa/s) with sine, square, pulse, ramp, noise, DC, and 200+ pre-loaded arbitrary waveforms plus a custom-waveform editor. Modulation and sweep modes support stimulus-response work, closed-loop stability sweeps paired with UPO7000L-PWR, and time-correlated stimulus-and-capture testing alongside scope acquisition — from within the same 1U rack-mount instrument.

UPO7000L optional power analysis
Optional UPO7000L-PWR: power quality, harmonic, switching loss, ripple, loop, SOA.

Power Analysis (Optional UPO7000L-PWR) — Six Measurement Types

For wide-bandgap (GaN, SiC) power-electronics validation at full 2 GHz analog bandwidth, high-frequency motor drives, fast-edge DC-DC converter characterization, and ATE-bench validation of high-frequency switching designs, the optional UPO7000L-PWR package extends the four-channel scope into a working power analyzer: power quality, harmonic analysis, switching loss across the cycle, ripple analysis, loop analysis (paired with the optional UPO7000L-AWG for closed-loop stability sweeps), and safe operating area visualization. The 2 GHz analog bandwidth captures fast-edge content on the latest commercial GaN and SiC switching devices where 1 GHz scopes start to limit accuracy.

Math Operations and MATLAB Integration

The UPO7000L provides a system of algorithms for complex waveform operations: enhanced FFT with time-domain, frequency-domain, and modulation-domain views; high-pass, low-pass, band-pass, and band-limit filters; user-defined function operations across digital channels, analog channels, and reference waveforms; and on-instrument MATLAB embedded programming with data presentation directly on the external display or via WebServer. Up to 8 math waveforms can run simultaneously, with built-in spectrum analysis and peak search alongside the standard automated measurements.

UPO7000L math operations and waveform processing
Math operations: enhanced FFT, filters (HP/LP/BP/BL), enhanced resolution, user-defined.
UPO7000L back-panel interfaces
USB Host x4, USB Device, dual LAN, HDMI, AUX, EXT, 10 MHz Ref, Audio.

Connectivity, SCPI, and Multi-Instrument Synchronization Hardware

USB Host (4: USB 2.0 ×2, USB 3.0 ×2), USB Device, dual LAN (10/100/1000 BASE-T) for redundant or load-balanced ATE network topologies, HDMI display output, AUX In/Out (trigger sync, AWG trigger, pass/fail), 10 MHz Ref In/Out for multi-instrument clock sync, EXT Trig BNC, and an audio I/O port. Full SCPI command set (USBTMC); built-in WebServer provides browser-based remote control from PC or smartphone over IP — view state, export waveform files, screenshot, and control via remote keyboard and mouse without driver installation. UNI-T provides synchronizer hardware as part of multi-channel integrated solutions for parallel-test ATE racks.

Applications

For R&D Engineers

  • For 2 GHz R&D validation in shared-lab and rack-based environments, the UPO7204L covers high-end FPGA and SoC silicon debug, high-speed digital interface characterization (DDR4/5 region, USB 3.0, PCIe Gen 1-2), four-channel time-correlated acquisition, and 11-protocol decode across the high-speed embedded design envelope — all from a 1U headless instrument under WebServer remote control. The optional UPO7000L-JITTER package adds eye-diagram analysis with clock recovery and full TJ/RJ/DJ/PJ/DDJ/DCD jitter decomposition for serial-link compliance work above ~1 Gbps.
  • Time-correlated four-channel acquisition under WebServer remote control from any browser, supporting shared-lab and rack-based engineering environments where bench surface is at a premium.
  • Eleven-protocol decode covering computer, automotive (CAN/CAN-FD/LIN/FlexRay/SENT), audio, and aerospace (MIL-STD-1553/ARINC 429) bus families with integrated trigger and decode.
  • UltraAcq® Sequence mode at 2,000,000 wfms/s for rare-event hunting on intermittent timing anomalies and signal-integrity work where 200,000 wfms/s scopes miss the event between redraws.

For ATE Integrators and Test Labs

  • For ATE system integrators, parallel high-channel-count semiconductor parametric test, aerospace/automotive validation programs, and high-throughput DVT/EVT work at the 2 GHz tier, the UPO7204L consolidates oscilloscope, spectrum analyzer, protocol decoder, AWG, jitter and eye-diagram analyzer (UPO7000L-JITTER), and power analyzer (UPO7000L-PWR) into one 1U rackmount instrument with multi-machine sync to 128 units / 512 channels. The 11-protocol decode set including aerospace (MIL-STD-1553, ARINC 429) and high-speed automotive (CAN-FD, FlexRay, SENT) covers customer-design validation in regulated industries.
  • Multi-machine synchronization up to 128 units / 512 channels with 200 ps RMS inter-instrument jitter for parallel high-channel-count test architectures impossible with benchtop scopes.
  • 1U half-width rack-mount form factor (two instruments per full-width slot) integrates into ATE racks alongside other 1U/2U test equipment; HDMI external display + WebServer remote control eliminate operator-presence requirements at the rack.
  • Standard mask & limit testing with configurable failure actions and integrated test report output supports DVT/EVT/ATP evidence reporting on first capture; full SCPI command set (USBTMC) and dual LAN for script-driven automated test sequences in redundant or load-balanced ATE network topologies.

Accessories & In the Box

Included

  • UT-P07A passive high-impedance probes (1X DC–8 MHz; 10X DC–500 MHz) × 4
  • UT-D30 USB 3.0 data cable
  • UT-L45 BNC-to-BNC straight-through cable × 2
  • National-standard power cable
  • Calibration certificate
  • Quick start guide

Available Options

Recommended Accessories

  • UT-PA2000 — 2 GHz active single-ended probe (10X, ≤1 pF input capacitance, ±7 V dynamic range) — engineered for the 7000-series
  • UT-P20 — 100 MHz, 100:1 high-voltage passive probe (1.5 kVrms)
  • UT-P21 — 50 MHz, 1000:1 high-voltage passive probe (DC 15 kVrms)
  • UT-P30 / UT-P31 / UT-P32 / UT-P33 — High-voltage differential probes (100/100/50/120 MHz)
  • UT-P40 / UT-P41 / UT-P42 / UT-P43 / UT-P44 — Current probes (100 kHz to 50 MHz)
  • UT-ISOT — Isolation transformer

Family Members

Frequently Asked Questions

Why a rack-mount oscilloscope instead of a benchtop instrument?

Rack-mount form factor solves a problem benchtop scopes structurally cannot: it integrates into ATE racks alongside other 1U/2U test instruments, frees bench surface in shared-lab environments, and supports parallel high-channel-count architectures via multi-machine sync (up to 128 units / 512 channels with 200 ps RMS inter-instrument jitter). For benchtop design-validation work where one operator drives one scope on one bench, a benchtop instrument is the right tool. For ATE racks running parallel parametric test on aerospace, automotive, or semiconductor designs, where rack density and channel-count scaling are the buying constraints, the 1U headless UPO7204L is purpose-engineered for that workflow. WebServer remote control over LAN means operator interaction happens from any browser; HDMI external display supports local visual debug when required.

What's the difference between standard capture rate and Sequence mode?

Standard capture rate (≥600,000 wfms/s via UltraAcq®) is the UPO7204L’s continuous real-time waveform acquisition rate. Sequence mode (2,000,000 wfms/s) uses segmented memory to capture multiple trigger-conditioned frames for post-capture replay — for rare-event hunting where the trigger is well-defined.

Design. Debug. Deploy.

Warranty

This instrument is backed by UNI-T's 3+2 Year Warranty — 3 years of standard coverage, plus 2 additional years free when you register your product. That's 5 years of total protection at no extra cost.

The warranty covers manufacturing defects and component failures under normal use conditions. UNI-T instruments are built for professional daily use, and our warranty reflects that commitment to long-term reliability.