UTS3015T+ / UTS3032T+ UTS3000T+ Performance-Series Spectrum Analyzer with Tracking Generator
Overview
The UTS3015T+ and UTS3032T+ bring 1.5 GHz and 3.2 GHz spectrum analysis, a built-in tracking generator, and reflection measurement into a single bench instrument under two thousand dollars. For a small hardware team or a contract test bench, that means one box covers signal search, scalar network checks, and pre-compliance screening without three separate purchases.
Both models hold a typical displayed average noise level to −161 dBm (preamp on, a shared series figure), phase noise below −98 dBc/Hz at 10 kHz offset, and full-amplitude accuracy under 0.7 dB — numbers that hold up under real measurement conditions, not peak-only figures. A 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN make the instrument scriptable from day one.
Tracking generator is built in on every T+ model — it is the defining difference of the T+ line and is standard, not an added option. Analog demodulation, the advanced measurement kit, and EMI pre-compliance remain field-installable options when a project needs them.
Choosing Your Model — UTS3000T+ Performance-Series
The UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:
| Specification | UTS3015T+ | UTS3032T+ | UTS3036T+ | UTS3084T+ |
|---|---|---|---|---|
| Frequency range | 9 kHz – 1.5 GHz | 9 kHz – 3.2 GHz | 9 kHz – 3.6 GHz | 9 kHz – 8.4 GHz |
| Sweep (scan) points | 10,001 | 10,001 | 40,001 | 40,001 |
| Traces | 4 | 4 | 6 | 6 |
| Analog demodulation (option) | AM, FM | AM, FM | AM, FM, PM | AM, FM, PM |
| Tracking generator range | 100 kHz – 1.5 GHz | 10 MHz – 3.2 GHz | 100 kHz – 3.6 GHz | 100 kHz – 6 GHz |
| Resolution bandwidth | 1 Hz – 3 MHz | 1 Hz – 3 MHz | 1 Hz – 3 MHz | 1 Hz – 3 MHz |
| Built-in tracking generator | Standard | Standard | Standard | Standard |
Within the UTS3015T+/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four, and PM demodulation in addition to AM/FM — confirm which class a model belongs to before assuming a shared specification.
Key Features
- Spectrum analysis to 1.5 GHz or 3.2 GHz — 9 kHz lower edge to a 1.5 GHz (UTS3015T+) or 3.2 GHz (UTS3032T+) upper edge, covering HF through the common sub-3 GHz ISM, IoT and wireless bands.
- Built-in tracking generator — Standard on both models — scalar frequency-response and insertion-loss measurement on filters, amplifiers and cables without a separate source.
- Reflection measurement (S11) — Return loss, VSWR and reflection coefficient with the optional VSWR bridge — antenna and cable checks on the same bench.
- −161 dBm typical DANL (preamp on) — Low displayed average noise level for weak-signal work near the noise floor — a shared series figure, identical across both models at their top frequencies.
- 1 Hz to 3 MHz resolution bandwidth — 1-3-10 steps with < 4.8:1 shape factor to separate closely spaced signals of unequal amplitude.
- 10,001 sweep points, four traces — Per-trace resolution across the full span with four independent traces and five detector modes.
- 10.1-inch multi-touch interface — 1280×800 capacitive screen with drag, pinch and zoom on the trace.
- Full SCPI remote control — USB and LAN (VXI11) with SCPI for scripted, repeatable test sequences.
- Option-extensible — Add analog demodulation, the advanced measurement kit, or EMI pre-compliance as the work requires.
UNI-T UTS3000T+ Performance-Series Details
Spectrum Coverage and the Built-in Tracking Generator
The UTS3015T+ sweeps 9 kHz to 1.5 GHz and the UTS3032T+ to 3.2 GHz. Both carry a built-in tracking generator (−40 dBm to 0 dBm output, 0.5 dB resolution), so a swept frequency-response measurement on a filter or amplifier is set up on the analyzer itself rather than wired to an external generator.

Built-in tracking generator output
Sensitivity for Weak-Signal Work
With the preamp enabled, typical displayed average noise level reaches −161 dBm (500 kHz to 200 MHz band). This is a shared series figure — both models hold the same typical noise floor at their respective top frequencies. A low noise floor is what lets a small signal be seen rather than buried, which matters for spur hunting and low-level emissions checks.

Low displayed average noise level
Resolution Bandwidth and Selectivity
RBW is settable from 1 Hz to 3 MHz in 1-3-10 steps. The < 4.8:1 (60 dB/3 dB) shape factor resolves adjacent signals of unequal amplitude — the case where a strong carrier would otherwise mask a nearby weak product.

RBW selectivity, unequal-amplitude signals
10,001-Point Sweep
Each trace carries 10,001 points across the selected span, giving the frequency resolution needed to catch narrow signals that a coarser sweep would step over.

10,001-point sweep
Reflection Measurement
With the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR. After an Open calibration, a marker on the trace reads the value at any frequency — enough for antenna tuning and cable-fault checks without a dedicated VNA.

S11 return loss / VSWR
10.1-inch Multi-Touch Operation
The 1280×800 capacitive screen supports drag, expand and zoom directly on the trace, with a fixed menu layout that keeps common settings one or two presses away.

10.1-inch capacitive touch
Applications
Contract Test Labs and Design Consultancies
For a single-digit-engineer shop, bench space and budget are both finite. One UTS3015T+ or UTS3032T+ covers signal search, scalar network response with the built-in tracking generator, return-loss checks with the reflection-measurement bridge, and — with the EMI option — early conducted/radiated screening before a formal CISPR run. SCPI over LAN drops it straight into a Python or LabVIEW acceptance-test procedure. No per-feature license conversations: the options are one-time installs, not recurring fees.
Bench RF Design and Validation
On a design bench, the same instrument verifies oscillator output, checks harmonic and spurious content against a target, characterizes a filter or matching network with the tracking generator, and confirms antenna match with the VSWR bridge. The < 0.7 dB full-amplitude accuracy and −161 dBm typical DANL mean the numbers used in a design-verification report hold up under the conditions they were measured in.
Specifications
| Parameter | UTS3015T+ | UTS3032T+ |
|---|---|---|
| Frequency range | 9 kHz to 1.5 GHz | 9 kHz to 3.2 GHz |
| Sweep span | 0 Hz, 100 Hz to 1.5 GHz | 0 Hz, 100 Hz to 3.2 GHz |
| Resolution bandwidth | 1 Hz to 3 MHz, 1-3-10 steps | |
| Video bandwidth | 1 Hz to 3 MHz, 1-3-10 steps | |
| Selectivity (60/3 dB) | < 4.8:1 (60 dB / 3 dB, nominal) | |
| Sweep points / trace | 10,001 | |
| Traces | 4 | |
| Detectors | Sample, Peak, Negative, Normal, Average | |
| DANL (typical, preamp on) | typical displayed average noise level to -161 dBm (preamp on, 500 kHz-200 MHz band; identical at each model's top frequency) | |
| Phase noise | < -98 dBc/Hz @ 10 kHz offset (typical) | |
| Full-amplitude accuracy | < 0.7 dB full-amplitude accuracy | |
| Reference level | -100 dBm to +30 dBm, 1 dB steps | |
| Preamplifier | 20 dB (nominal) | |
| Input attenuator | 0 to 51 dB, 1 dB step | |
| Max safe input | 50 V DC; <= +33 dBm (3 min, input attenuation > 20 dB) | |
| Tracking generator range | 100 kHz to 1.5 GHz | 10 MHz to 3.2 GHz |
| TG output level | -40 dBm to 0 dBm, 0.5 dB resolution, +/-3 dB flatness | |
| Reflection measurement | VSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration | |
| Analog demod (option) | AM, FM — UTS3015T+ 2 MHz to 1.5 GHz, UTS3032T+ 2 MHz to 3.2 GHz | |
| Advanced measurement kit (option) | Channel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor / spectrogram | |
| EMI pre-compliance (option) | CISPR RBWs 200 Hz/9 kHz/120 kHz/1 MHz; Peak/Neg-Peak/Quasi-Peak/EMI-Avg/Avg detectors; editable limit lines | |
| Display | 10.1-inch 1280x800 capacitive multi-touch panel | |
| Interfaces | USB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10/100/1000Base RJ-45, HDMI 1.4 | |
| Remote control | Full SCPI remote control over USB / LAN | |
| Dimensions / weight | 378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg | |
| Operating temperature | 0 C to +40 C operating; -20 C to +70 C non-operating | |
| Calibration period | 12 months recommended | |
Accessories and Family Options
The tracking generator is built in on every UTS3015T+ / UTS3032T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.
Frequently Asked Questions
Does the tracking generator cost extra on the T+?
No. The tracking generator is built in and standard on every UTS3000T+ model, including the UTS3015T+ and UTS3032T+. It is the defining feature of the T+ line.
What is the difference between the UTS3015T+ and the UTS3032T+?
Frequency reach and sensitivity. The UTS3015T+ covers 9 kHz to 1.5 GHz; the UTS3032T+ covers 9 kHz to 3.2 GHz. Both models share the same typical noise floor at their top frequencies, plus the same 10,001-point sweep engine, four traces, RBW range, touch interface and built-in tracking generator. The difference is frequency reach: 1.5 GHz versus 3.2 GHz. See Choosing Your Model above.
Can it do EMI pre-compliance?
With the optional UTS3000-EMI kit, yes. It adds CISPR-bandwidth RBWs (200 Hz, 9 kHz, 120 kHz, 1 MHz), quasi-peak and EMI-average detectors and editable limit lines for screening with a near-field probe set before a formal compliance run.
How is it controlled remotely?
Full SCPI over USB or LAN (VXI11). It integrates with Python, LabVIEW and MATLAB through standard VISA.
Warranty
This instrument is backed by UNI-T's 3+2 Year Warranty — 3 years of standard coverage, plus 2 additional years free when you register your product. That's 5 years of total protection at no extra cost.
The warranty covers manufacturing defects and component failures under normal use conditions. UNI-T instruments are built for professional daily use, and our warranty reflects that commitment to long-term reliability.
Data Sheets and Manuals
Software / Firmware Downloads
Authentic UNI-T accessories are an affordable way to extend the functionality of your instrument.
UTS3000B Options 4
Need to add specific functionality to your UNI-T instrument? Here are our options for specific applications and measurement types. Have a question? Contact us at 888-668-UniT (8648).
Spectrum Analyzer Accessories 18

BAG-B3 Carry Bag for UTD UTS1000/3000 MSO/UPO1000/2000/3000 Models
$65.00
UT-3009F Female VNA Calibration Kit (9 GHz)
$999.00
UT-3009F/M Female-Male VNA Calibration Kit (9 GHz)
$1,699.00
UT-3009M Male VNA Calibration Kit (9 GHz)
$999.00
UT-C01-6 GHz Adapter
$29.00
UT-C02-4 GHz Adapter
$29.00
UT-C03-18 GHz Adapter
$79.00
UT-C04-40 GHz Adapter
$79.00
UT-CK01 Utility Kit
$249.00
UT-CK02 Utility Kit
$369.00
UT-RB60 6 GHz VSWR Reflection Bridge for Spectrum Analyzers
$299.00
UT-VNA18-3.5M-NM VNA Test Cable Kit (18 GHz)
$499.00
UT-W01-6 GHz N-N RF Cable
$55.00
UT-W02-6 GHz N-SMA RF Cable
$55.00
UT-W03-40 GHz RF Cable
$339.00
UTS-EMI01 Near-Field Probe Kit
$429.00
UTS-T01 Antenna
$15.00