UTS-EMI02 9 kHzβ50 MHz Near-Field Probe Kit
Overview
The UTS-EMI02 is a three-probe magnetic near-field kit covering 9 kHz to 50 MHz, for finding where interference comes from on a board, cable or enclosure. Used with a spectrum analyzer, the probes show magnetic field strength over components, coupling paths and leakage around a case.
It covers the band below the UTS-EMI01 (30 MHz to 3 GHz): the region where switching-supply fundamentals and their low harmonics sit.
Key Features
- 9 kHz to 50 MHz across three probes β NFP-1.5M-P3 for 9 kHz to 1.5 MHz, NFP-50M-P1 for 1 MHz to 50 MHz, and NFP-50M-P2 for close-in work.
- Two resolutions β about 25 mm for the larger loops, about 10 mm for the NFP-50M-P2 to pinpoint a single component.
- Detection distance β up to 10 cm for P1 and P3, 3 cm for P2.
- 50 Ξ© signal path β SMB probe connectors, a 1 m SMA-to-SMB cable and an SMA-to-N adaptor for the analyzer's RF input.
- Carry case β 230 Γ 180 Γ 45 mm, under 1 kg.
UTS-EMI02 Details
Connecting the kit
Connect the SMB end of the cable to the probe and the SMA end to the adaptor, then fit the adaptor's N connector to the spectrum analyzer's RF input. Hold the probe close to the device under test without touching it, and watch the placement direction of the loop as you scan.
Applications
- Pre-compliance EMI debug β find which component, trace or cable is radiating before a lab test.
- Switching power supplies β localize magnetic fields around inductors, transformers and switching loops.
- Enclosure leakage β check seams, vents and cable entries for leakage.
Compatibility
Fits any spectrum analyzer with an N-type RF input. On UNI-T analyzers, the EMI pre-compliance options (UTS1000-EMI, UTS5000A-EMI, UTS7000A-EMI) add EMI measurement functions for pre-compliance scans.
Frequently Asked Questions
How does it differ from the UTS-EMI01?
The UTS-EMI02 covers 9 kHz to 50 MHz with three magnetic-field probes. The UTS-EMI01 covers 30 MHz to 3 GHz. Together they span 9 kHz to 3 GHz.
What is in the kit?
Three near-field probes (NFP-50M-P1, NFP-50M-P2, NFP-1.5M-P3), one SMA-to-SMB RF cable and one SMA-to-N adaptor.
Is there a preamplifier?
No preamplifier is listed in the kit. The probes connect to the analyzer through the 50 Ξ© cable and adaptor.
| Frequency Range | 9kHz - 50MHz |
|---|---|
| Instrument Type | Near-Field Probe Kit |
Full specifications (8)
| Details | |
|---|---|
| Components | NFP-50M-P1|NFP-50M-P2|NFP-1.5M-P3 |
| Connector Type | SMB male (probe), SMA female (adaptor), N male (to analyzer) |
| Input Impedance | 50Ξ© |
| Storage Temperature | -20Β°C - 70Β°C |
| General Information | |
| Operating Temperature | 0Β°C - 50Β°C |
| Dimensions (WΓHΓD) | 230mmΓ180mmΓ45mm |
| Weight | <1kg |
| Warranty | 1 year |