{"product_id":"upo6058lp","title":"UPO6058LP 500 MHz 8Ch 12-Bit Rack-Mount Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UPO6058LP is a 12-bit, 500 MHz bandwidth, 8-channel high-resolution oscilloscope on UNI-T's UPO6000LP 1U rack-mount platform. The chassis interleaves to 5 GSa\/s, holds 500 Mpts\/CH of memory, and captures 500,000 waveforms per second (up to 1 M wfm\/s in sequence mode) through the Ultra Phosphor 3.0 display engine. The 12-bit native ADC delivers 4× the vertical resolution of an 8-bit scope at every gain setting — small-signal detail resolves without the gain shifts that 8-bit instruments require to recover it.\u003c\/p\u003e\n\u003cp\u003eThe UPO6058LP ships in an 8-channel configuration. The chassis supports the optional single-phase and three-phase power analysis suites — neither is available on the 4-channel chassis. Twelve serial protocol families decode across industrial, automotive, computer, embedded, and audio buses. The 1U headless form factor stacks into 19-inch racks and synchronizes to other chassis for combined-channel capture.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model — UPO6000LP High-Resolution Oscilloscopes\u003c\/h2\u003e\n\u003cp\u003eAll six UPO6000LP models share the same 12-bit native ADC, 5 GSa\/s interleaved sample rate, 500 Mpts\/CH memory depth, 500,000 wfm\/s capture rate, Ultra Phosphor 3.0 display, 56-parameter measurement suite, and 1U headless rack-mount chassis. The matrix below shows the differentiators that vary across the family — bandwidth determines rise time and the highest-frequency content the front end resolves; channel count determines which advanced options the chassis can carry. The 4-channel chassis accepts the optional built-in 50 MHz AWG; the 8-channel chassis accepts the single-phase and three-phase power analysis options.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:25%\"\u003e\n\u003ccol style=\"width:37.5%\"\u003e\n\u003ccol style=\"width:37.5%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003cth\u003e4 channels\u003cbr\u003e\u003cspan style=\"font-weight:normal;font-size:0.9em\"\u003eAWG option supported\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth\u003e8 channels\u003cbr\u003e\u003cspan style=\"font-weight:normal;font-size:0.9em\"\u003ePower analysis options supported\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 GHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUPO6104LP\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤0.35 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\nUPO6108LP\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤0.35 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e500 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUPO6054LP\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤0.70 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUPO6058LP\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤0.70 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e350 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUPO6034LP\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤1.00 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\nUPO6038LP\u003cbr\u003e\u003cspan style=\"font-size:0.9em\"\u003eRise time ≤1.00 ns\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-bit native vertical resolution\u003c\/strong\u003e at every gain setting — 4× the dynamic range of an 8-bit scope, with HR mode extending effective resolution to 16 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz analog bandwidth\u003c\/strong\u003e with ≤0.70 ns rise time (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 GSa\/s real-time sample rate\u003c\/strong\u003e interleaved, 2.5 GSa\/s non-interleaved on each channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts\/CH maximum memory depth\u003c\/strong\u003e — capture tens of thousands of waveform cycles in a single acquisition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s capture rate\u003c\/strong\u003e via Ultra Phosphor 3.0; 1,000,000 wfms\/s in sequence mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 analog channels\u003c\/strong\u003e on a 1U headless rack-mount chassis with HDMI display output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-phase advanced power analysis\u003c\/strong\u003e option — 13 measurement types including switching loss, Rds(on), surge current, and SOA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase power analysis\u003c\/strong\u003e option — synchronous voltage and current capture with space-vector diagram (8-channel models only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 serial protocol families\u003c\/strong\u003e — RS232\/422\/485\/UART, I²C, and SPI standard; CAN, CAN-FD, LIN, FlexRay, SENT, audio, MIL-STD-1553, ARINC429, and Manchester optional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 automated parameter measurements\u003c\/strong\u003e with histogram and trend statistics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone triggering and hardware-accelerated mask test\u003c\/strong\u003e for intermittent-anomaly isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 Mpts FFT\u003c\/strong\u003e for spectrum analysis up to the Nyquist limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-machine synchronization\u003c\/strong\u003e — combine up to 16 UPO6000LP chassis for 64-channel (4-ch) or 128-channel (8-ch) acquisition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Host (×4), USB Device, LAN (VXI-11), HDMI, 10 MHz reference in\/out\u003c\/strong\u003e — full SCPI 1999.0 \/ IEEE-488.2 control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWebServer remote control\u003c\/strong\u003e from PC or mobile device, plus free UNI-T instrument management software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UPO6058LP Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_ultraphosphor3.jpg\" alt=\"Ultra Phosphor 3.0 waveform persistence display showing dense signal activity\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 persistence display — 500,000 wfm\/s standard, 1 M wfm\/s sequence\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e12-Bit Native Resolution with Ultra Phosphor 3.0 Display Engine\u003c\/h3\u003e\n\u003cp\u003eVertical resolution is 12 bits native at every gain setting. An 8-bit oscilloscope offers 256 ADC codes; the 12-bit ADC provides 4,096 codes — 4× the dynamic range and 16× the amplitude granularity. Low-amplitude features on a high-amplitude carrier resolve directly without rescaling the input range. HR (high-resolution) acquisition mode raises effective resolution further, up to 16 bits.\u003c\/p\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's proprietary capture and display engine. Multi-bank interleaved mapping and a segmented matrix processing architecture push capture rate to 500,000 wfm\/s in standard mode, 1,000,000 wfm\/s in sequence mode. Information-entropy-based abnormal-signal detection runs in hardware, so intermittent events that appear once per million cycles land in the persistence buffer rather than going missed between triggers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAll-in-One Instrument Platform\u003c\/h3\u003e\n\u003cp\u003eThe UPO6058LP integrates multiple instruments into one chassis: digital storage oscilloscope, hardware frequency counter (7-digit, multi-channel), 4-digit RMS voltmeter, FFT spectrum analyzer (up to 5 Mpts), 56-parameter automated measurement suite, serial protocol decoder (12 families), and timing analyzer. The 4-channel configuration adds an optional 50 MHz function\/arbitrary waveform generator. Each function uses the same calibrated front end, eliminating impedance and timebase drift between separate instruments.\u003c\/p\u003e\n\u003cp\u003eBench space, BNC inventory, calibration overhead, and inter-instrument synchronization consolidate into one chassis — cross-domain debug across voltage waveform, frequency content, protocol decode, and parameter trend on one time axis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_8-in-1.jpg\" alt=\"UPO6000LP all-in-one instrument integration showing oscilloscope, AWG, counter, DVM, FFT, and decode\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eMultiple instruments integrated into one calibrated chassis\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_zone_1.jpg\" alt=\"Zone trigger display showing rectangular trigger region drawn around an anomalous waveform feature\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eZone triggering — isolate intermittent anomalies by drawing a region on screen\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eZone Triggering — Isolate Intermittent Anomalies\u003c\/h3\u003e\n\u003cp\u003eZone triggering captures intermittent anomalies that conventional trigger logic cannot isolate. Engineers draw a rectangular zone on the touch UI or via SCPI and the instrument captures only waveforms that enter (or avoid) the zone. The behavior simplifies debug for glitches, runt pulses, jitter excursions, and protocol field violations that standard edge or pattern triggers cannot pin to a stable display.\u003c\/p\u003e\n\u003cp\u003eTwo zones combine with Boolean logic — capture only waveforms entering zone A AND zone B, or A AND NOT B. The zones travel with the waveform across acquisitions; once a fault is defined it stays captured for the test duration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e12 Serial Protocols with Decode, Trigger, and Event Search\u003c\/h3\u003e\n\u003cp\u003eTwelve serial protocol families are decodable. Three ship standard: RS232\/422\/485\/UART, I²C, and SPI. The remaining nine are licensed options: CAN and CAN-FD (industrial and motor drives), LIN (low-speed sensor networks), FlexRay (deterministic distributed control), SENT, audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553, ARINC 429, and Manchester.\u003c\/p\u003e\n\u003cp\u003eProtocol decode pairs with serial-bus trigger and protocol-event search — find a specific frame ID or data payload across the full memory depth without paging through millions of cycles manually. Decoded data exports as a conformance report for design verification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_protocols.jpg\" alt=\"Multi-protocol serial bus decode display showing simultaneous decode of multiple bus types\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e12 serial protocol families with trigger, decode, and event search\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_parameters.jpg\" alt=\"56-parameter measurement display with histogram and trend plot for each measured parameter\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e56 automated measurements with histogram and trend statistics\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e56-Parameter Measurement Suite with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003eThe instrument supports 56 automated parameter measurements covering voltage, time, area, frequency, slew rate, duty cycle, jitter, eye-pattern parameters, and statistical aggregates. Up to 27 parameters display simultaneously; 9 parameters per page show full statistics including measured value, histogram of the distribution, and trend plot over time. The parameter snapshot function captures 39 measurements for a single channel in one read.\u003c\/p\u003e\n\u003cp\u003eThree measurement strategies — amplitude, top-value, and base-value — tune how the instrument computes parameters on noisy, modulated, or non-flat-top signals. A burst-setup function adds burst-specific parameters (burst width, repetition rate, intra-burst period) for pulsed and packetized signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eHardware-Accelerated Mask Test\u003c\/h3\u003e\n\u003cp\u003eMask test compares each acquired waveform against a tolerance template and counts pass\/fail in hardware. The test uses an FPGA-resident comparator and runs at full waveform-capture rate — testing that takes minutes on software-only platforms completes in seconds on the UPO6000LP. Mask shapes are user-defined or imported from compliance specifications.\u003c\/p\u003e\n\u003cp\u003ePass\/fail output is wired through the AUX BNC for production-line integration; the instrument can stop on first fail, count to a threshold, or log failure waveforms to USB while continuing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_mask.jpg\" alt=\"Hardware-accelerated mask test display with tolerance template overlaid on captured waveform\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eFPGA-resident mask test — runs at full capture rate\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_math.jpg\" alt=\"Mathematical operations display showing arithmetic, filter, and FFT outputs\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eMath operations, digital filters, and 5 Mpts FFT\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eMath, Digital Filters, and 5 Mpts FFT\u003c\/h3\u003e\n\u003cp\u003eThe math system supports the four arithmetic operations between analog channels (+, −, ×, ÷), four digital filter types (high-pass, low-pass, band-pass, band-limit) with user-set cutoff and order, and custom function operations that combine multiple channels through user-defined expressions. Math waveforms are full-rate and can be used as trigger or measurement sources.\u003c\/p\u003e\n\u003cp\u003eFFT spectrum analysis runs up to 5 Mpts with five window functions, displaying magnitude, phase, real, or imaginary content with cursor and peak-search — sufficient to resolve narrow spectral features at high span and to support EMI pre-compliance work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSearch and Navigate Across 500 Mpts of Memory\u003c\/h3\u003e\n\u003cp\u003eCapturing 500 Mpts of memory per channel means hours of waveform activity in a single acquisition. The search engine indexes user-defined events — edges, pulse widths, runt pulses, protocol decode values, mask violations — across the entire memory and lets the user step between matches with the navigation controls.\u003c\/p\u003e\n\u003cp\u003eSearch and navigation pair with the zoom architecture; the engineer jumps from event to event at full resolution without leaving the record. Events are bookmarked and exported with the waveform file for later analysis on a connected PC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_search.jpg\" alt=\"Search and navigate display showing event markers across deep memory waveform record\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eEvent search across 500 Mpts of memory with navigation\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_rack.jpg\" alt=\"1U rack-mount UPO6000LP chassis stacked in 19-inch instrument rack\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e1U rack-mount form factor — stacks into 19-inch racks\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_sync.jpg\" alt=\"Multi-machine synchronization diagram showing combined channel capture across multiple chassis\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eMulti-machine sync — up to 16 chassis combined\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e1U Rack-Mount Chassis and Multi-Machine Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe UPO6058LP is a 1U headless rack-mount chassis — no integrated display, no front-panel keys beyond the power button. Control is via the external touch display (HDMI), the WebServer interface (LAN or USB), or SCPI from a host system. The 1U form factor stacks into 19-inch racks; multiple chassis share one bench display via KVM.\u003c\/p\u003e\n\u003cp\u003eMulti-machine synchronization combines up to 16 chassis into a coordinated acquisition system — 64 channels (4-ch) or 128 channels (8-ch). The sync subsystem distributes timebase, trigger, and 10 MHz reference across the rack; cross-chassis measurements share one time axis without external delay-line compensation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eWebServer Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eThe UPO6058LP runs an embedded WebServer accessible from any browser on the same network. Open the chassis IP in a PC or mobile browser and the instrument's display, controls, and waveform data render in the browser. SCPI commands route through the same interface for automation; waveform files and the user manual download directly to the host. The architecture eliminates the need for a vendor-specific driver or installer for casual remote access.\u003c\/p\u003e\n\u003cp\u003eHigher-throughput automation runs through the SCPI 1999.0 \/ IEEE-488.2 command set over USB-Device or LAN (VXI-11). LabVIEW, Python-VISA, and any standard ATE framework integrate directly. The free UNI-T instrument management software for Windows handles bulk waveform pull, settings save\/restore, and firmware update.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_webserver.jpg\" alt=\"WebServer remote control interface displayed in browser showing oscilloscope display and controls\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eWebServer remote control from PC or mobile browser\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_power_analyzer.jpg\" alt=\"Single-phase and three-phase power analysis displays with measurement readouts and space-vector diagram\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003ePower analysis — single-phase (13 types) and three-phase with space-vector display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePower Analysis and Three-Phase Power Analysis (Optional, 8-Channel Only)\u003c\/h3\u003e\n\u003cp\u003eThe UPO6058LP supports the optional UPO6000LP-PWR single-phase power analysis — 13 measurement types: power quality, harmonics, switching loss, Rds(on), SOA, surge current, slew rate, modulation, ripple, transient response, efficiency, turn-on\/off time, and timing. Values compute from the voltage and current channels with connected probes; no external wattmeter needed.\u003c\/p\u003e\n\u003cp\u003eThe optional UPO6000LP-3PWR three-phase package adds synchronous voltage and current sampling across all three phases — power quality, harmonic analysis, ripple, efficiency, and DQ0 analysis with space-vector display. Real-time display accelerates debug of motor drives, EV inverters, and grid-tied power conversion. Both options are 8-channel-only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePrimary Applications\u003c\/h2\u003e\n\u003ch3\u003eMulti-Channel R\u0026amp;D Validation and Debug\u003c\/h3\u003e\n\u003cp\u003eThe 12-bit ADC and 5 GSa\/s sample rate make the UPO6058LP a primary debug instrument for mixed-signal designs where small-signal detail matters. Low-amplitude noise on a high-amplitude rail, slow droop on a switching transient, and protocol-field margin violations all resolve at one gain setting without rescaling. The 500 Mpts memory holds a full debug session for after-the-fact search.\u003c\/p\u003e\n\u003ch3\u003eATE Integration and Long-Duration Automated Test\u003c\/h3\u003e\n\u003cp\u003eThe headless 1U rack-mount chassis is built for automated test environments. SCPI 1999.0 \/ IEEE-488.2 over LAN (VXI-11) or USB integrates with LabVIEW, Python-VISA, and any major ATE framework. Hardware-accelerated mask test runs pass\/fail at full capture rate; the AUX output drives production-line bin sorters directly. Multi-machine sync scales channel count for parallel device-under-test stations sharing one timebase.\u003c\/p\u003e\n\u003ch3\u003ePower Integrity and Switching Power Supply Characterization\u003c\/h3\u003e\n\u003cp\u003eThe 8-channel chassis supports the single-phase and three-phase power analysis options. Combined with 12-bit vertical resolution, the instrument resolves switching-loss waveforms, Rds(on) ramps, and inrush currents that 8-bit scopes compress into noise. Three-phase analysis captures motor drives and inverters on three voltage and three current channels with real-time space-vector display.\u003c\/p\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eUPO6000LP Family Members\u003c\/h3\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:18%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:26%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003cth\u003eCh\u003c\/th\u003e\n\u003cth\u003eRise time\u003c\/th\u003e\n\u003cth\u003eAWG opt\u003c\/th\u003e\n\u003cth\u003ePower opts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPO6108LP\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e≤0.35 ns\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPO6104LP\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e≤0.35 ns\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5\"\u003e\n\u003ctd\u003eUPO6058LP\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e≤0.70 ns\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPO6054LP\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e≤0.70 ns\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPO6038LP\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e≤1.00 ns\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPO6034LP\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e≤1.00 ns\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO6000LP-PWR — Single-phase advanced power analysis (8-channel chassis only)\u003c\/li\u003e\n\u003cli\u003e\nUPO6000LP-3PWR — Three-phase power analysis with space-vector diagram (8-channel chassis only)\u003c\/li\u003e\n\u003cli\u003e\nUPO6000LP-TIMING — Timing analyzer for bus communication timing (I²C, SPI, CAN, I²S)\u003c\/li\u003e\n\u003cli\u003eUPO6000LP-CAN, UPO6000LP-CANFD, UPO6000LP-LIN, UPO6000LP-FLEX, UPO6000LP-SENT — Automotive and industrial serial bus decode options\u003c\/li\u003e\n\u003cli\u003eUPO6000LP-AUDIO — Audio bus decode option (I²S, left\/right justified, TDM)\u003c\/li\u003e\n\u003cli\u003eUPO6000LP-MIL1553, UPO6000LP-ARINC429, UPO6000LP-MANCH — Additional serial bus decode options\u003c\/li\u003e\n\u003cli\u003eUPO6000LP-BND — Software analysis bundle\u003c\/li\u003e\n\u003cli\u003eUPO6000LP-AUTO — Vehicle bus diagnostic bundle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Probes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-P08A — 600 MHz passive voltage probe (for 350 MHz and 500 MHz chassis)\u003c\/li\u003e\n\u003cli\u003e\nUT-P09A — 1.5 GHz passive voltage probe (for 1 GHz chassis)\u003c\/li\u003e\n\u003cli\u003e\nUT-PA2000 — 2 GHz active single-ended voltage probe\u003c\/li\u003e\n\u003cli\u003e\nUT-P40 series — AC\/DC current probes (range 20 A to 500 A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does \"headless rack-mount\" mean — do I need an external display?\u003c\/h3\u003e\n\u003cp\u003eThe UPO6000LP chassis is a 1U rack-mount form factor with no integrated display. Operation is via an external touch display on the HDMI port, the WebServer interface in any browser, or SCPI from a host system. The headless architecture trades the front-panel screen for rack density — multiple chassis share one bench display through a KVM switch.\u003c\/p\u003e\n\u003ch3\u003eCan I synchronize multiple UPO6000LP chassis?\u003c\/h3\u003e\n\u003cp\u003eYes. Up to 16 chassis combine on a shared timebase, trigger, and 10 MHz reference — 64 channels (4-ch) or 128 channels (8-ch). The chassis present as one combined acquisition system to the SCPI controller.\u003c\/p\u003e\n\u003ch3\u003eDoes the 8-channel model include a built-in waveform generator?\u003c\/h3\u003e\n\u003cp\u003eNo. The built-in 50 MHz AWG is 4-channel-only; the 8-channel chassis cannot accept the Gen option. For 8-channel applications requiring AWG stimulus, an external UNI-T UTG-series benchtop AWG pairs with the chassis over LAN or USB.\u003c\/p\u003e\n\u003ch3\u003eWhat's the difference between standard and sequence-mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate is 500,000 wfm\/s — new waveforms acquired and processed into the persistence display in real time. Sequence mode raises capture rate to 1,000,000 wfm\/s by storing memory segments to a high-speed buffer for post-acquisition display. Sequence mode is preferred for intermittent-event capture; standard mode for continuous-trace persistence work.\u003c\/p\u003e\n\u003ch3\u003eDo I need specific probes for the power analysis option?\u003c\/h3\u003e\n\u003cp\u003eThe power analysis software runs on whatever voltage and current probes are connected. For switching-supply work, pair a high-voltage differential probe (UT-PA series) with an AC\/DC current probe (UT-P40 series, sized to the load). The chassis computes analysis from the captured channels — probe selection determines accuracy and bandwidth, not feature availability.\u003c\/p\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_ultraphosphor3.jpg\" alt=\"Ultra Phosphor 3.0 waveform persistence display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 persistence display — 500,000 wfm\/s standard, 1 M wfm\/s sequence\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_8-in-1.jpg\" alt=\"UPO6000LP all-in-one instrument integration\"\u003e\u003cspan class=\"lightbox-caption\"\u003eMultiple instruments integrated into one calibrated chassis\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_zone_1.jpg\" alt=\"Zone trigger display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eZone triggering — isolate intermittent anomalies\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_protocols.jpg\" alt=\"Multi-protocol serial bus decode display\"\u003e\u003cspan class=\"lightbox-caption\"\u003e12 serial protocol families with trigger, decode, and event search\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_parameters.jpg\" alt=\"56-parameter measurement display\"\u003e\u003cspan class=\"lightbox-caption\"\u003e56 automated measurements with histogram and trend statistics\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_mask.jpg\" alt=\"Hardware-accelerated mask test display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eFPGA-resident mask test — runs at full capture rate\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_math.jpg\" alt=\"Mathematical operations display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eMath operations, digital filters, and 5 Mpts FFT\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_search.jpg\" alt=\"Search and navigate display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eEvent search across 500 Mpts of memory with navigation\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_rack.jpg\" alt=\"1U rack-mount UPO6000LP chassis\"\u003e\u003cspan class=\"lightbox-caption\"\u003e1U rack-mount form factor — stacks into 19-inch racks\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_sync.jpg\" alt=\"Multi-machine synchronization diagram\"\u003e\u003cspan class=\"lightbox-caption\"\u003eMulti-machine sync — up to 16 chassis combined\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6000LP_webserver.jpg\" alt=\"WebServer remote control interface\"\u003e\u003cspan class=\"lightbox-caption\"\u003eWebServer remote control from PC or mobile browser\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_power_analyzer.jpg\" alt=\"Power analysis display showing single-phase and three-phase measurements with space-vector diagram\"\u003e\u003cspan class=\"lightbox-caption\"\u003ePower analysis — single-phase and three-phase with space-vector display\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPO6058LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz (-3 dB, 50 Ω termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise time (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.70 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s interleaved; 2.5 GSa\/s non-interleaved per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts per channel maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits native; up to 16 bits in HR mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µV\/div to 10 V\/div (1 MΩ); 500 µV\/div to 1 V\/div (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform capture rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfm\/s standard; 1,000,000 wfm\/s in sequence mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit, multi-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial protocol decode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 families (3 standard, 9 optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\/arbitrary waveform generator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot available on 8-channel chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional UPO6000LP-PWR (13 single-phase measurements); UPO6000LP-3PWR (5 three-phase measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal via HDMI; chassis is headless 1U rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host ×4, USB Device, LAN (VXI-11), HDMI, AUX (Trig\/Pass-Fail\/DVM), EXT trigger, 10 MHz Ref In\/Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWebServer, SCPI 1999.0 \/ IEEE-488.2, UNI-T instrument management software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-machine synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 16 chassis (128 channels combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U rack-mount, headless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=126\"\u003eUPO6058LP Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":54133695316252,"sku":"181100200253X","price":13599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO6008LP_1.png?v=1779302434","url":"https:\/\/uni-trendus.com\/products\/upo6058lp","provider":"Uni-Trend US","version":"1.0","type":"link"}