{"product_id":"udp6952b","title":"UDP6952B 600W 60V\/25A Programmable DC Switching Power Supply","description":"\u003ch1\u003eUNI-T UDP6952B DC Switching Power Supply\u003c\/h1\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe UDP6952B is UNI-T's 600W high-current programmable DC switching supply — 60V at up to 25A continuous, sized for e-bike and light-EV motor drive testing, fast-charging stage prototyping, and 48V industrial battery work. Auto-range output delivers any V\/I combination within the 600W envelope from a single instrument.\u003c\/p\u003e\n\u003cp\u003eFull programmable interface set: USB Device, USB Host, RS-232, RS-485, LAN with web control, and external analog I\/O — with SCPI, Multi-SCPI, and Modbus RTU command support. Built-in 4½-digit DVM monitors a second voltage point on the DUT without an external instrument. Slope control configures rise\/fall rates independently in voltage-slope (VSR) and current-slope (ISR) modes for soft start\/stop. Remote sense (S+\/S−) compensates for IR drop on the test leads. List mode and delayer functions program up to 512 voltage\/current\/time groups, stored to internal Flash or USB.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAcross the Design. Debug. Deploy.™ Lifecycle\u003c\/h2\u003e\n    \u003cdiv class=\"product-row\"\u003e\n      \u003cdiv class=\"product-box product-left\"\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign.\u003c\/strong\u003e Sourcing the bench supply for high-current 60V power-electronics development is the first commit. 600 W at 60 V \/ 25 A with 1 mV \/ 0.1 mA resolution covers the envelope this work needs, with the four-wire sense and slope-controlled startup that DUT-protective work requires from the first turn-on. Programmable from the front panel or remotely — list mode, slope control, OVP\/OCP, and DVM are first-class controls, not buried menu options.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDebug.\u003c\/strong\u003e At validation, the 4½-digit DVM and 512-group list mode replace a second DMM and an external sequencer. Capture power-up profiles, automate sweeps, and record DUT-side voltage drift while sourcing — without leaving the supply's front panel or rebuilding the test harness.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDeploy.\u003c\/strong\u003e Production go\/no-go testing runs over LAN with SCPI, Multi-SCPI, or Modbus RTU. The web server gives a shared bench remote access without a host-software install. RS-485 multi-machine networking scales the station as the throughput requirement does. From first prototype to production verification — design, debug, deploy.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"product-box product-right\"\u003e\n        \u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-phase-frame\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP6952B_1.jpg\" alt=\"UDP6952B for design, debug, deploy lifecycle\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6952B — from prototype bench to production rack\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-phase-frame\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP6952B_1.jpg\" alt=\"UDP6952B for design, debug, deploy lifecycle\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6952B — from prototype bench to production rack\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e600W Auto-Range Output (0–60V, 0–25A)\u003c\/strong\u003e — Flexible V\/I combinations within rated power. One supply handles multiple test configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy \u0026amp; Low Ripple\u003c\/strong\u003e — 1 mV\/0.1 mA resolution with low ripple and noise for sensitive DUT testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVP\/OCP Protection\u003c\/strong\u003e — Independent over-voltage and over-current protection with configurable thresholds protects devices under test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eList Mode \u0026amp; Delay Function\u003c\/strong\u003e — Program voltage\/current sequences with configurable timing for automated test profiles and battery charge simulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlope Control\u003c\/strong\u003e — Configurable rise\/fall rates for soft start\/stop, preventing inrush damage to sensitive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Sense\u003c\/strong\u003e — Four-wire sensing compensates for voltage drop in test leads, ensuring accurate voltage at the load terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In DVM\u003c\/strong\u003e — Independent digital voltmeter for monitoring a second voltage point without additional equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Remote Control \u0026amp; Multi-Machine\u003c\/strong\u003e — Browser-based control via LAN. Master\/slave communication for series\/parallel multi-unit configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFront-Panel Interface\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eA 4.3-inch true color LCD shows set voltage and current alongside actual output values, with output power computed and displayed in real time. The numeric keypad sets values directly without menu diving; the rotary encoder fine-tunes when a small adjustment is faster than typing. Soft-keys map to the function actually in use — list mode, slope, OVP\/OCP, or DVM — instead of burying them in nested menus. Output enable is a dedicated hardware button, always visible, never one click away from a keystroke mistake.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-multifunctional-inte\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP6952B_1.jpg\" alt=\"UDP6952B front panel\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6952B front panel — keypad, encoder, and dedicated soft-keys\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-multifunctional-inte\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP6952B_1.jpg\" alt=\"UDP6952B front panel\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6952B front panel — keypad, encoder, and dedicated soft-keys\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eRemote Sense\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eLong test leads drop voltage. At higher currents, the drop is no longer a rounding error — a 10 A draw across a meter of 16 AWG returns roughly 50 mV less to the load than the supply set. The UDP6900 series corrects for this with four-wire remote sense: connect the output's \u003cstrong\u003e+\u003c\/strong\u003e and \u003cstrong\u003e−\u003c\/strong\u003e terminals to the load through the current-carrying leads, then run a separate pair from \u003cstrong\u003eS+\u003c\/strong\u003e and \u003cstrong\u003eS−\u003c\/strong\u003e directly to the device under test. The supply servo's regulation point shifts from its own terminals to the load's terminals — and the 1 V SENSE compensation headroom keeps the rail accurate where it actually matters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-img10\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162270\/UDP6900_Remote_Sense.jpg\" alt=\"UDP6900 Remote Sense\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Remote Sense\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-img10\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162270\/UDP6900_Remote_Sense.jpg\" alt=\"UDP6900 Remote Sense\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Remote Sense\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOver-Voltage\/Over-Current Protection (OVP\/OCP)\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eIndependent over-voltage and over-current thresholds, both set from the front panel. When either limit trips, the supply latches output off and posts the trigger on the LCD — the kind of unambiguous fault state that matters when a DUT failure during overnight characterization could otherwise damage hardware or lose a test run. Thresholds persist across power cycles and survive front-panel lock for unattended operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-over-voltage-over-cu\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162266\/UDP6900_OVP.jpg\" alt=\"UDP6900 OVP\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Protection Modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-over-voltage-over-cu\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162266\/UDP6900_OVP.jpg\" alt=\"UDP6900 OVP\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Protection Modes\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eList Output and Delay Function\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eList mode programs up to 512 voltage\/current\/time groups, executed in sequence — useful at 25 A continuous for low-voltage inverter input-stage characterization (walking through 12 V, 24 V, and 48 V system levels at full current draw), for high-current DC-DC converter input sweeps, and for controlled-current battery discharge profiles. The delay function programs output on\/off sequencing for load-cycling reliability tests. Files save to Flash or USB in \u003ccode\u003e.lst.csv\u003c\/code\u003e and \u003ccode\u003e.dly.csv\u003c\/code\u003e formats — Excel-editable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-list-output-and-dela\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162264\/UDP6900_Delayer.jpg\" alt=\"UDP6900 Delayer\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Delayer\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-list-output-and-dela\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162264\/UDP6900_Delayer.jpg\" alt=\"UDP6900 Delayer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Delayer\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eSlope Mode Options\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eAt 25 A continuous, an uncontrolled current rise into an inductive or low-impedance load is a real fault risk. Three slope modes prevent it. Normal mode steps directly to the set value. Voltage Slope (VSR) ramps voltage at a configurable rate. Current Slope (ISR) ramps current step-by-step — critical for motor-drive bench setups, low-voltage inverter input stages, and any DUT where startup di\/dt determines whether the DUT runs or fails the SOA gate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-img7\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162258\/UDP6900_Slope_Mode.jpg\" alt=\"UDP6900 Slope Mode\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Slope Mode\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-img7\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162258\/UDP6900_Slope_Mode.jpg\" alt=\"UDP6900 Slope Mode\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Slope Mode\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAuto Range Functionality\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003e600 W of working envelope, with output reconfiguration across the V\/I plane on demand: 60 V at 10 A for high-side characterization, 25 A at 24 V for low-voltage inverter input stages, or anything in between. At 25 A continuous, the UDP6952B handles current ranges that fixed supplies in the 100–200 W class simply cannot reach — without sacrificing the upper voltage when the bench needs it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-auto-range-functiona\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162267\/UDP6900_Auto_Range.jpg\" alt=\"UDP6900 Auto Range\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Auto Range\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-auto-range-functiona\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162267\/UDP6900_Auto_Range.jpg\" alt=\"UDP6900 Auto Range\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Auto Range\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eBuilt-in Digital Voltmeter (DVM)\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eA built-in 4½-digit voltmeter measures DC voltage on a separate rear-panel pair, displayed alongside the supply's own readbacks on the LCD. For a two-rail bench scenario — measuring the load's regulated DC at the same time the supply is sourcing it — the DVM eliminates a second instrument. Range is 0.001–65.000 V on the 60 V models, up to 160 V on the UDP6933B and UDP6953B.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-built-in-digital-vol\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162269\/UDP6900_DVM.jpg\" alt=\"UDP6900 DVM\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 DVM\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-built-in-digital-vol\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162269\/UDP6900_DVM.jpg\" alt=\"UDP6900 DVM\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 DVM\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eMultiple Main Menu Options\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe main menu structure is shallow by design. Five top-level sections — Monitor, System Settings, User Group, Output Settings, Language — each one or two presses from the front panel. Monitor displays live V\/I\/P\/DVM with per-channel alarms when set conditions deviate. Output Settings configure operating mode, power-up output, and slope. System Settings hold backlight, sound, RS-232\/network, and a factory-default restore. The menu hierarchy never exceeds two levels — depth defeats front-panel work, and the UDP6900 doesn't ask the operator to memorize trees.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-multiple-main-menu-o\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162263\/UDP6900_Settings.jpg\" alt=\"UDP6900 Settings\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Settings\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-multiple-main-menu-o\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162263\/UDP6900_Settings.jpg\" alt=\"UDP6900 Settings\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Settings\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eComputer Software and Remote Control\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UDP6900 series ships with free PC control software — UNI-T's UDP9000 host application, common across the programmable PSU line. Set voltage and current remotely, log readbacks to disk, sequence list and delay programs, and automate complete characterization runs without writing a SCPI parser. For scripted environments, the supply speaks SCPI, Multi-SCPI, and Modbus RTU natively over USB-Device, RS-232, RS-485, or LAN — pick the bus that fits the test station.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-computer-software-an\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162262\/UDP6900_Software.jpg\" alt=\"UDP6900 Software\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-computer-software-an\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162262\/UDP6900_Software.jpg\" alt=\"UDP6900 Software\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Software\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eMulti-Machine Communication\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eRS-485 networking links multiple UDP6900 supplies to a single host. Master\/slave configurations enable series-stack for higher voltage or parallel-stack for higher current — useful for multi-rail bench setups or when a single test station needs more total power than one chassis provides. One SCPI session, many supplies, synchronized output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-multi-machine-commun\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162261\/UDP6900_Multi-machine.jpg\" alt=\"UDP6900 Multi-machine\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Multi-machine\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca id=\"lb-udp6952b-multi-machine-commun\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162261\/UDP6900_Multi-machine.jpg\" alt=\"UDP6900 Multi-machine\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUDP6900 Multi-machine\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWeb Control\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eLAN connection brings up an embedded web server — open the supply's IP in any browser to set parameters, run list and delay programs, and configure system settings. No vendor application install on the host machine, no driver headache when the bench runs Linux or a tablet workstation. For shared lab benches and remote-monitored automation, the browser interface is often the cleanest path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eUDP6900 Web Control\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-udp6952b-hero\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162260\/UDP6900_Web_Control.jpg\" alt=\"\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-udp6952b-hero\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1726162260\/UDP6900_Web_Control.jpg\" alt=\"\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e\u003c\/span\u003e\n\u003c\/a\u003e\n\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eHigh-Current Motor Drive \u0026amp; EV Bench\u003c\/h3\u003e\n\u003cp\u003e25 A continuous at 60 V handles e-bike and light-EV motor drive testing, fast-charging stage prototyping, 48V mild-hybrid automotive electronics, and 600W industrial-scale bench work. Slope control prevents current overshoot during DUT power-up.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eBattery Charging \u0026amp; Pack Emulation\u003c\/h3\u003e\n\u003cp\u003eProgrammable CC\/CV with list mode runs realistic charge profiles up to 25A. The supply can also act as a battery emulator with controlled output impedance for downstream charger and BMS testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eIndustrial Power Electronics Bench\u003c\/h3\u003e\n\u003cp\u003e600W output suits 48V\/60V industrial DC equipment, high-power DC-DC converter dev, and the higher-end of low-voltage power-electronics work. Multi-machine RS-485 scales the bench for multi-unit configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTest Lab \u0026amp; Production Test\u003c\/h3\u003e\n\u003cp\u003eFull SCPI over USB, RS-232, RS-485, and LAN integrates into automated test systems. Web control via browser. External analog interface for multi-supply coordination. Internal Flash + USB storage for test profiles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does auto-range mean?\u003c\/p\u003e\n\u003cp\u003eAuto-range means the supply delivers any voltage\/current combination within the rated 600W envelope. The UDP6952B can output 60V at reduced current or 25A at reduced voltage — the power limit is the constraint, not fixed V\/I maximums independently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UDP6700 and UDP6900B series?\u003c\/p\u003e\n\u003cp\u003eThis family (UDP6900B) sits above the UDP6700, adding auto-range output, slope control, built-in DVM, web control over LAN, RS-485 for multi-machine networking, USB Device, Modbus RTU, and external analog control. UDP6700 provides the core CV\/CC + list-mode + remote-compensation feature set with RS-232 SCPI at a lower price.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I connect multiple UDP6900B units for higher power?\u003c\/p\u003e\n\u003cp\u003eYes. Multi-machine communication via RS-485 enables master\/slave configurations — connect units in series for higher voltage or parallel for higher current, controlled from a single master or via SCPI commands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UDP6952B?\u003c\/p\u003e\n\u003cp\u003eThe UDP6952B ships with the instrument, power cable Test leads and sense leads available separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":49243888648476,"sku":"181400100153X","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP6952B_1_sq.jpg?v=1723076173","url":"https:\/\/uni-trendus.com\/products\/udp6952b","provider":"Uni-Trend US","version":"1.0","type":"link"}