{"product_id":"mso3054x","title":"MSO3054X 500 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eMSO3054X | 500 MHz 4-Channel Mixed Signal Oscilloscope\u003c\/h1\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe MSO3054X is a 500 MHz, four-channel mixed-signal oscilloscope. With 5 GSa\/s real-time sample rate, 500 Mpts of acquisition memory, 16 logic-analyzer channels (with the optional \u003ca href=\"\/products\/ut-m15\"\u003eUT-M15 probe pod\u003c\/a\u003e), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO3054X consolidates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor wide-bandwidth power-electronics design, mixed-signal validation across faster MCU and FPGA silicon, switching-converter characterization at the 100s of MHz tier, and small-lab consolidation across multiple instrument categories, the MSO3054X is the top SKU in the MSO3000X line. Calculated rise time falls to ≤0.7 ns — fast enough to resolve the leading edges on wide-bandgap (GaN, SiC) switching devices and the rise-time content of high-speed digital signals where 350 MHz scopes start to round corners. The 12-protocol decode set extends to aerospace serial buses (MIL-STD-1553B, ARINC 429, Manchester) for design-phase work on avionics, defense electronics, and instrumentation systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 500 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤0.7 ns — fast enough to capture leading-edge content on GaN and SiC switching devices, high-speed digital interfaces, and full-bandwidth signal-integrity analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 800,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 1.25 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and six-measurement power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/422\/485\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocol Decoding\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, and Manchester — 12 protocols total across computer, automotive, audio, aerospace, and wireless domains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the \u003ca href=\"\/products\/ut-m15\"\u003eUT-M15 logic probe pod\u003c\/a\u003e; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG with Bode Plot\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with the Bode plot analyzer included for closed-loop frequency-response analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic, plus eleven additional trigger types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-nine_in_one\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO3000X_9-in-1a.png\" alt=\"MSO3000X nine integrated instruments\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eNine instruments integrated: scope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO3000X integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional \u003ca href=\"\/products\/ut-m15\"\u003eUT-M15 probe pod\u003c\/a\u003e), 50 MHz dual-channel function and arbitrary waveform generator (optional), 1.25 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit DVM, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer covering 12 bus types, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and a six-measurement power-electronics analyzer (optional). For lab benches and small-lab consolidations covering scope, spectrum, protocol decode, AWG-driven stimulus, power analysis, and Bode-plot loop analysis — instruments that would otherwise occupy four to six rack slots and four to six calibration cycles — the integration condenses the bench footprint into one operator surface and one calibration event. For independent test labs validating customer designs across multiple categories, the consolidated nine-instrument view is the operational differentiator.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-nine_in_one\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO3000X_9-in-1a.png\" alt=\"MSO3000X nine integrated instruments\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine instruments integrated: scope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 500 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave) and 500 Mpts of acquisition memory hold full waveform fidelity across the 500 MHz analog bandwidth. Standard capture rate runs up to 800,000 wfms\/s; in Sequential Mode — the segmented-memory mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, recording up to 200,000 frames for post-capture replay and analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-high_speed_engine\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_DSO_Screen.png\" alt=\"MSO3000X high-speed oscilloscope display\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003e800,000 wfms\/s standard; 2,000,000 wfms\/s in Sequential Mode.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-high_speed_engine\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_DSO_Screen.png\" alt=\"MSO3000X high-speed oscilloscope display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e800,000 wfms\/s standard; 2,000,000 wfms\/s in Sequential Mode.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts Per Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe 500 Mpts memory depth supports the deepest acquisition windows in the MSO3000X line at full sample rate — capturing tens of thousands of waveforms in a single acquisition for post-event analysis. With Sequential Mode recording up to 200,000 frames, rare-event hunting on high-traffic protocol buses and switching-converter transient capture across long fault-recovery cycles becomes a defined operation rather than a wait-and-watch exercise. For independent test labs validating customer designs, the deep-memory budget makes pass\/fail evidence reports comprehensive on the first capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eVertical Resolution — 8-Bit Native with ERES to 12-Bit\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054X uses an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available — useful for low-amplitude signal work where quantization noise would obscure detail on switching ripple, sensor outputs, or jitter analysis at the higher-bandwidth tier. For applications requiring native 12-bit resolution at full 500 MHz bandwidth, see UNI-T’s \u003ca href=\"\/collections\/mso3000hd\"\u003eMSO3000HD-series scopes\u003c\/a\u003e, which use the R12™ native 12-bit ADC architecture for power-electronics ripple-on-bias measurements where the signal-of-interest sits on a high-amplitude DC offset.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture: parallel FPGA acquisition with 256-level grayscale intensity grading, a 20 Gbps internal data path, and sub-1 µs dead time. The scope captures fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. Intensity grading shows frequency-of-occurrence directly — frequent waveforms appear brighter, infrequent ones dimmer — making intermittent faults easy to distinguish from normal behavior.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-spectrum\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Spectrum_Analyzer.png\" alt=\"MSO3000X built-in spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003e0 Hz to 1.25 GHz, 4 Mpts FFT, four traces, four detections, waterfall.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 1.25 GHz with up to 4 Mpts FFT length, four-channel analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Markers plus a waterfall display track spectral activity over time — for harmonic ID, EMI pre-compliance sweeps, clock-purity verification, and modulated-signal analysis without the cable swap a separate spectrum analyzer requires.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-spectrum\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Spectrum_Analyzer.png\" alt=\"MSO3000X built-in spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e0 Hz to 1.25 GHz, 4 Mpts FFT, four traces, four detections, waterfall.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eProtocol Analysis — 12 Bus Types Across Five Domains\u003c\/h3\u003e\n\u003cp\u003eTwelve protocols across five bus domains: computer serial (RS-232\/422\/485\/UART, I²C, SPI — standard); automotive (CAN, CAN-FD, LIN, FlexRay, SENT — optional); audio (I²S, LJ, RJ, TDM — optional); aerospace (MIL-STD-1553B, ARINC 429 — optional); and Manchester wireless (optional). Triggering and decoding are integrated — trigger on a frame error, identifier match, CRC failure, or missing-ack condition, and the decode displays inline with the captured waveform. The aerospace and Manchester decode set differentiates this protocol envelope from mid-tier scopes that stop at automotive and audio.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-protocols\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Protocol_Analyzer.png\" alt=\"MSO3000X protocol analyzer with event list and search\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003e12 protocols across computer, automotive, audio, aerospace, and wireless domains.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-protocols\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Protocol_Analyzer.png\" alt=\"MSO3000X protocol analyzer with event list and search\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e12 protocols across computer, automotive, audio, aerospace, and wireless domains.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-awg_bode\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_AWG.png\" alt=\"Optional dual-channel AWG with Bode plot analyzer\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eMSO3000X-AWG: 50 MHz, 2-channel, 16-bit, 250 MSa\/s; Bode plot analyzer included.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO3000X-AWG package adds a 50 MHz dual-channel function\/arbitrary waveform generator (16-bit, 250 MSa\/s) plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with AM, FM, ASK, FSK, and sweep modulation. On-screen captures load directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-awg_bode\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_AWG.png\" alt=\"Optional dual-channel AWG with Bode plot analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMSO3000X-AWG: 50 MHz, 2-channel, 16-bit, 250 MSa\/s; Bode plot analyzer included.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis (Optional) — Six Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor wide-bandwidth power-electronics validation on GaN and SiC switching converters, high-frequency motor drives, and full-bandwidth DC-DC characterization, the optional power-analysis package extends the four-channel scope acquisition into a working power analyzer: power quality measurement, harmonic analysis to the 50th order, switching loss across the cycle, ripple analysis on output rails, loop analysis (paired with the Bode plot included with the optional AWG) for closed-loop stability sweeps, and safe operating area visualization for device-stress validation. At 500 MHz of analog bandwidth, the package handles the switching frequencies that wide-bandgap converters and high-speed PoL designs operate at.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-power_analysis\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Power_Analyzer.png\" alt=\"MSO3000X optional power analyzer\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003eOptional MSO3000X-PWR: power quality, harmonics, switching loss, ripple, loop, SOA.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-power_analysis\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Power_Analyzer.png\" alt=\"MSO3000X optional power analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOptional MSO3000X-PWR: power quality, harmonics, switching loss, ripple, loop, SOA.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition. With eleven additional trigger types (edge, pulse width, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), zone triggering turns rare-event hunting into a defined acquisition.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e54 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e54 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 displayed simultaneously. Statistics include mean, max, min, standard deviation, count, tendency chart, and histogram. The burst function reports values across burst segments — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eFast Fuzzy Autoset\u003c\/h3\u003e\n\u003cp\u003eThe fuzzy-logic autoset algorithm uses the 7-digit hardware frequency counter and multi-channel parallel processing to lock onto unknown signals quickly: all-channel autoset in under 1.5 seconds, single-channel under 1 second — meaningful on production-line spot-check work and engineering benches that swap test articles often.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\u003ca href=\"#lb-mso3054x-touch_ui\" class=\"product-thumb-link\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Multi_Window.png\" alt=\"MSO3000X multi-window touch interface\" class=\"product-image-thumb\"\u003e\n\u003c\/a\u003e\n\u003cfigcaption class=\"product-figcaption\"\u003e10.1-inch 1280×800 capacitive multi-touch with multi-window layout.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets waveform, FFT, decode-list, and measurement-table panels be dragged and resized independently. Knob-and-key controls remain; HDMI output mirrors the display to an external monitor or projector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ca id=\"lb-mso3054x-touch_ui\" href=\"#_\" class=\"product-lightbox\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO2000X_3000X_Multi_Window.png\" alt=\"MSO3000X multi-window touch interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e10.1-inch 1280×800 capacitive multi-touch with multi-window layout.\u003c\/span\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device, LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). Full SCPI command set; the built-in WebServer provides browser-based remote control from PC or mobile without driver installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor wide-bandwidth R\u0026amp;D validation at 500 MHz, the MSO3054X covers ARM Cortex-A and FPGA-class silicon debug, four-channel time-correlated mixed-signal work (with the \u003ca href=\"\/products\/ut-m15\"\u003eUT-M15 logic probe pod\u003c\/a\u003e), and full-bandwidth protocol decode where the rise-time edge of the analog signal-integrity story matters — faster microcontroller reference designs, FPGA peripherals at higher data rates, embedded-Linux SoC validation, and high-speed digital bus characterization.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the \u003ca href=\"\/products\/ut-m15\"\u003eUT-M15 probe pod\u003c\/a\u003e) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003e12-protocol decode set covering computer, automotive, audio, aerospace, and Manchester-wireless buses; up to four simultaneous decodes plus event list and search.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches; eleven trigger types cover the full embedded-systems debug envelope.\u003c\/li\u003e\n\u003cli\u003e500 Mpts memory captures long acquisition windows for protocol-event hunting and post-event analysis; Sequential Mode records up to 200,000 frames of triggered events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Power Electronics Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor wide-bandgap (GaN, SiC) power-electronics design, full-bandwidth motor-drive validation, high-speed DC-DC converter characterization, and fast-edge switching analysis, the MSO3054X pairs 500 MHz of analog bandwidth with the optional six-measurement power-analysis suite, the optional 50 MHz AWG and Bode plot analyzer for closed-loop stability sweeps, and 200,000-frame Sequential Mode for fault-event capture across long transient windows — the full converter-design workflow on one instrument.\u003c\/li\u003e\n\u003cli\u003eOptional six-measurement power-analysis package: power quality, harmonic analysis, switching loss, ripple analysis, loop analysis, and safe operating area visualization.\u003c\/li\u003e\n\u003cli\u003eFour-channel acquisition supports vIN \/ vOUT \/ IL \/ vGS measurement on switching converters and DC-DC supplies in a single time-correlated capture.\u003c\/li\u003e\n\u003cli\u003eOptional dual-channel 50 MHz AWG with Bode plot analyzer for closed-loop frequency-response and stability sweeps on power-supply controllers.\u003c\/li\u003e\n\u003cli\u003eSequential Mode captures 200,000 frames of triggered events for fault-recovery and burst-mode analysis on intermittent power events and load-step transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Test Labs and Design Consultancies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor independent test labs and design consultancies validating customer designs across multiple instrument categories, the MSO3054X consolidates oscilloscope, spectrum analyzer, protocol decoder, AWG, Bode plot analyzer, and power analyzer on one operator surface — reducing rack count and calibration overhead while covering the standard test-lab measurement envelope. The 12-protocol decode set (including MIL-STD-1553B, ARINC 429, and Manchester) supports aerospace and defense-electronics validation work that mid-tier scopes leave on the option list.\u003c\/li\u003e\n\u003cli\u003eNine-in-one consolidation reduces rack count and calibration overhead across scope, spectrum, protocol decode, AWG, Bode plot, and power-analysis categories on independent test benches.\u003c\/li\u003e\n\u003cli\u003e12-protocol decode set including aerospace (MIL-STD-1553B, ARINC 429) and Manchester-wireless covers customer-design validation work that mid-tier scopes leave on the option list.\u003c\/li\u003e\n\u003cli\u003eSCPI command set and WebServer remote control support script-driven automated test sequences and remote-bench workflows for distributed lab teams.\u003c\/li\u003e\n\u003cli\u003eSequential Mode 200,000-frame recording and 500 Mpts deep memory make pass\/fail evidence reports comprehensive on the first capture — reducing customer-bench rework.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P07A (500 MHz, 10:1) × 4 passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mso3000x-awg\"\u003eMSO3000X-AWG\u003c\/a\u003e — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mso3000x-pwr\"\u003eMSO3000X-PWR\u003c\/a\u003e — Power analysis package (6 measurement types)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mso3000x-bnd\"\u003eMSO3000X-BND\u003c\/a\u003e — Full serial-bus triggering and decoding bundle (AUTO + AUDIO + MIL-STD + ARINC429 + MANCH)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mso3000x-auto\"\u003eMSO3000X-AUTO\u003c\/a\u003e — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eIndividual protocol licenses: \u003ca href=\"\/products\/mso3000x-can\"\u003eCAN\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-canfd\"\u003eCAN-FD\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-lin\"\u003eLIN\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-flex\"\u003eFlexRay\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-sent\"\u003eSENT\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-audio\"\u003eAUDIO\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-mil1553\"\u003eMIL1553\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-arinc429\"\u003eARINC429\u003c\/a\u003e, \u003ca href=\"\/products\/mso3000x-manch\"\u003eMANCH\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-m15\"\u003eUT-M15\u003c\/a\u003e — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-pa2000\"\u003eUT-PA2000\u003c\/a\u003e — 2 GHz active probe (auto-sense attenuation, ±8 V offset range)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-p07a\"\u003eUT-P07A\u003c\/a\u003e — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-p20\"\u003eUT-P20\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p21\"\u003eUT-P21\u003c\/a\u003e — High-voltage probes\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-p30\"\u003eUT-P30\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p31\"\u003eUT-P31\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p32\"\u003eUT-P32\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p33\"\u003eUT-P33\u003c\/a\u003e — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-p40\"\u003eUT-P40\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p41\"\u003eUT-P41\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p42\"\u003eUT-P42\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p43\"\u003eUT-P43\u003c\/a\u003e \/ \u003ca href=\"\/products\/ut-p44\"\u003eUT-P44\u003c\/a\u003e — Current probes\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-isot\"\u003eUT-ISOT\u003c\/a\u003e — Isolation transformer\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ut-m13x\"\u003eUT-M13X\u003c\/a\u003e — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members and Related Scopes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mso3034x-350mhz-4ch-mso\"\u003eMSO3034X (350 MHz, 4-channel)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/mso7000x\"\u003eMSO7000X-series (1 GHz \/ 2 GHz)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (800,000 wfms\/s) is the rate at which the MSO3054X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 200,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined.\u003c\/p\u003e\n\n\u003ch3\u003eHow does the MSO3054X compare to the MSO3000HD-series scopes?\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054X and the MSO3000HD-series share the same 4-channel mixed-signal platform at 200–500 MHz and the same 9-in-1 multi-instrument feature set. The architectural difference is the ADC: the MSO3054X uses an 8-bit native ADC with up to 12-bit ERES; the MSO3000HD-series uses UNI-T’s R12™ native 12-bit ADC at full bandwidth. Choose the MSO3054X when 500 MHz bandwidth and 12-protocol decode breadth (including aerospace buses) are the priorities. Choose an MSO3000HD-series scope when the design requires native 12-bit resolution at full bandwidth — for example, ripple-on-bias measurement on a 400 V DC rail where the signal of interest sits on a large DC offset that 8-bit dynamic range cannot resolve cleanly.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp class=\"product-series-link\"\u003eSee more in the \u003ca href=\"\/collections\/mso3000x\"\u003eMSO3000X collection\u003c\/a\u003e, or browse all UNI-T \u003ca href=\"\/collections\/digital-oscilloscopes\"\u003edigital oscilloscopes\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp class=\"product-tagline\"\u003e\u003cstrong\u003eDesign. Debug. Deploy.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"181100300085X","offer_id":53216106447132,"sku":"181100300085X","price":3599.0,"currency_code":"USD","in_stock":true},{"title":"181100300069X","offer_id":53216106479900,"sku":"181100300069X","price":3599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO3054X_Bundle.jpg?v=1768593666","url":"https:\/\/uni-trendus.com\/products\/mso3054x","provider":"Uni-Trend US","version":"1.0","type":"link"}