{"title":"UPO6000LP Rack-Mount Oscilloscopes","description":"\u003ch1 class=\"bg-h1\"\u003eUNI-T Rack-Mount Oscilloscope — Buyer's Guide\u003c\/h1\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eWhich Rack-Mount Scope Is Right for You?\u003c\/h2\u003e\n\u003cp\u003eUNI-T builds two rack-mount oscilloscope series for system integration, ATE, and high-density validation: the \u003cstrong\u003eUPO6000LP\u003c\/strong\u003e (12-bit high-definition) and the \u003cstrong\u003eUPO7000L\u003c\/strong\u003e (8-bit lab-grade). Both are 1U chassis with rear connectivity, headless operation, and bench-equivalent acquisition engines. The choice between them comes down to \u003cstrong\u003eresolution vs. bandwidth\u003c\/strong\u003e: 12-bit precision or higher bandwidth and deeper memory.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eWhat Both Series Share\u003c\/h2\u003e\n\u003cdiv class=\"bg-sg\"\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eForm Factor\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003e1U rack-mount, fits standard 19\" instrument racks\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eOperation\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eHeadless — full control via LAN, SCPI, web interface\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eConnectivity\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eLAN, USB-Host, USB-Device, SCPI\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eBuilt For\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eATE, production test, system integration, continuous monitoring\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eMulti-Unit Sync\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eSynchronized stacking to scale channel count\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eAcquisition Engine\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eBench-equivalent — no form-factor compromise\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eProtocol Decode\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003eUART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay (optional)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-si\"\u003e\n\u003cdiv class=\"bg-sl\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"bg-sv\"\u003e3+2 years\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eBoth deliver UNI-T's full benchtop feature set in a rack-friendly chassis. The differences are vertical resolution, bandwidth ceiling, and channel density.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eDecision 1: Resolution or Bandwidth?\u003c\/h2\u003e\n\u003cdiv class=\"bg-vs\"\u003e\n\u003cdiv class=\"bg-v\"\u003e\n\u003ch3\u003eUPO6000LP — 12-Bit HD\u003c\/h3\u003e\n\u003cp\u003eVertical resolution of \u003cstrong\u003e12 bits\u003c\/strong\u003e — 16× the detail of an 8-bit scope. Bandwidth from 350 MHz to 1 GHz, 4 or 8 analog channels, 5 GSa\/s, 500 Mpts memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose if you\u003c\/strong\u003e need precision at lower amplitudes (switching ripple, power integrity, low-level signal characterization) or high channel density in a 1U chassis. The 8-channel models double the channel count of competing rack-mount scopes — ideal for multi-rail power monitoring and parallel bus capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-v\"\u003e\n\u003ch3\u003eUPO7000L — Lab-Grade 8-Bit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1 GHz or 2 GHz\u003c\/strong\u003e bandwidth with 10 GSa\/s sample rate and 1 Gpts memory — 2× the memory and up to 2× the bandwidth of the UPO6000LP. 8-bit resolution, 4 channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose if you\u003c\/strong\u003e need high-speed acquisition (fast edges, RF signals, high-speed serial protocols), long captures at full sample rate, or synchronized stacking for very high channel-count ATE installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eDecision 2: Pick Your Model\u003c\/h2\u003e\n\u003cp\u003eEach model name encodes its specs. UPO\u003cstrong\u003e61\u003c\/strong\u003e08\u003cstrong\u003eLP\u003c\/strong\u003e = 1 GHz, 8 channels, Low-Profile rack-mount. UPO\u003cstrong\u003e72\u003c\/strong\u003e04\u003cstrong\u003eL\u003c\/strong\u003e = 2 GHz, 4 channels, rack-mount Lab-grade.\u003c\/p\u003e\n\n\u003ch3\u003eUPO6000LP — 12-Bit Rack-Mount\u003c\/h3\u003e\n\u003cdiv class=\"bg-mc\"\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6034lp\"\u003eUPO6034LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e350 MHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e4 channels\u003c\/strong\u003e — entry HD rack-mount, power-integrity monitoring\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6038lp\"\u003eUPO6038LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e350 MHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e8 channels\u003c\/strong\u003e — multi-rail monitoring at 350 MHz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6054lp\"\u003eUPO6054LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e500 MHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e4 channels\u003c\/strong\u003e — mid-bandwidth precision applications\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6058lp\"\u003eUPO6058LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e500 MHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e8 channels\u003c\/strong\u003e — 8 channels at 500 MHz, switching converter validation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6104lp\"\u003eUPO6104LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e1 GHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e4 channels\u003c\/strong\u003e — top-of-line HD bandwidth, 4 channels\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo6108lp\"\u003eUPO6108LP\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e1 GHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e8 channels\u003c\/strong\u003e — flagship HD rack-mount, 8 channels at 1 GHz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eUPO7000L — Lab-Grade Rack-Mount\u003c\/h3\u003e\n\u003cdiv class=\"bg-mc\"\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo7104l\"\u003eUPO7104L\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e1 GHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e4 channels\u003c\/strong\u003e — 1 GHz at 10 GSa\/s with 1 Gpts memory\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-m\"\u003e\n\u003ch3\u003e\u003ca href=\"\/products\/upo7204l\"\u003eUPO7204L\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv class=\"bg-mf\"\u003e2 GHz\u003c\/div\u003e\n\u003cdiv class=\"bg-md\"\u003e\n\u003cstrong\u003e4 channels\u003c\/strong\u003e — flagship 2 GHz lab-grade rack-mount\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eComplete Model Comparison\u003c\/h2\u003e\n\u003ctable class=\"bg-tbl\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eBandwidth\u003c\/th\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003cth\u003eSample Rate\u003c\/th\u003e\n\u003cth\u003eMemory\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eIdeal For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6034lp\"\u003e\u003cstrong\u003eUPO6034LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eHD entry, power integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6038lp\"\u003e\u003cstrong\u003eUPO6038LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eMulti-rail monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6054lp\"\u003e\u003cstrong\u003eUPO6054LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eMid-BW HD validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6058lp\"\u003e\u003cstrong\u003eUPO6058LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eSwitching converter test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6104lp\"\u003e\u003cstrong\u003eUPO6104LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eHD top spec, 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo6108lp\"\u003e\u003cstrong\u003eUPO6108LP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003ctd\u003eHD flagship, 8 channels at 1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo7104l\"\u003e\u003cstrong\u003eUPO7104L\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e10 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e1 Gpts\u003c\/td\u003e\n\u003ctd\u003e8-bit\u003c\/td\u003e\n\u003ctd\u003eLab-grade ATE, 1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/upo7204l\"\u003e\u003cstrong\u003eUPO7204L\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GHz\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e10 GSa\/s\u003c\/td\u003e\n\u003ctd\u003e1 Gpts\u003c\/td\u003e\n\u003ctd\u003e8-bit\u003c\/td\u003e\n\u003ctd\u003eTop-spec lab-grade ATE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eRecommended Configurations\u003c\/h2\u003e\n\u003cdiv class=\"bg-ag\"\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eSwitching Power Supply Validation\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo6058lp\"\u003eUPO6058LP\u003c\/a\u003e or \u003ca href=\"\/products\/upo6108lp\"\u003eUPO6108LP\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e12-bit resolution surfaces ripple, transient response, and crossover detail that 8-bit smooths away. 8 channels cover multi-rail SMPS and synchronous-rectifier topologies in a single chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eEV \/ Battery Test Station\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo6038lp\"\u003eUPO6038LP\u003c\/a\u003e + DC loads + DAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e8-channel 12-bit precision for cell-balancing analysis, BMS communication, and inverter waveform integrity. Rack-mount form factor stacks with electronic loads and DC sources.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eHigh-Speed ATE \/ Production Test\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo7104l\"\u003eUPO7104L\u003c\/a\u003e or \u003ca href=\"\/products\/upo7204l\"\u003eUPO7204L\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1 Gpts memory captures long protocol sequences at full sample rate. 2 GHz bandwidth covers high-speed serial standards. Synchronized stacking scales channel count for fixture-mounted UUTs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eMulti-Rail Power Integrity\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo6108lp\"\u003eUPO6108LP\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e8 channels of 12-bit at 1 GHz — monitor every rail on a multi-supply system simultaneously without juggling probes or stacking scopes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eRF \/ High-Speed Serial Validation\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo7204l\"\u003eUPO7204L\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 GHz analog bandwidth with 10 GSa\/s captures the fast edges and RF signals 12-bit scopes can't reach. Optional jitter and eye-diagram analysis for compliance work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-ac\"\u003e\n\u003ch3\u003eContinuous Monitoring \/ Datalogging\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/upo6034lp\"\u003eUPO6034LP\u003c\/a\u003e or \u003ca href=\"\/products\/upo7104l\"\u003eUPO7104L\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHeadless operation with SCPI scripting makes long-running automated capture trivial. Rear connectivity keeps cabling clean in a permanent installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eWhy Choose UNI-T Rack-Mount?\u003c\/h2\u003e\n\u003cdiv class=\"bg-dg\"\u003e\n\u003cdiv class=\"bg-dc\"\u003e\n\u003ch3\u003e1U With No Compromise\u003c\/h3\u003e\n\u003cp\u003eSame acquisition engine and analysis features as UNI-T's benchtop scopes. The form factor saves rack space — it doesn't strip performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-dc\"\u003e\n\u003ch3\u003eHeadless by Design\u003c\/h3\u003e\n\u003cp\u003eBuilt for SCPI and web-based remote operation from the start. No touchscreen tax on rack depth, no front-panel workarounds — the scope is the API.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-dc\"\u003e\n\u003ch3\u003eChannel Density Choice\u003c\/h3\u003e\n\u003cp\u003eUPO6000LP's 8-channel models double the channel count of competing 1U scopes. One chassis covers multi-rail systems that would otherwise need stacked instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-dc\"\u003e\n\u003ch3\u003e5-Year Coverage\u003c\/h3\u003e\n\u003cp\u003e3-year warranty plus 2-year extension on every unit — covers the long deployment cycles of ATE and production test installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"bg-wrap\"\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eCan I mix UPO6000LP and UPO7000L in one rack?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Both are 1U chassis with the same SCPI interface and can coexist in any combination on the same LAN segment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eDoes either series support a local display?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBoth are headless by design. Remote control via SCPI or web interface is the primary workflow. A monitor can be connected for setup if needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eHow is multi-unit synchronization handled?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eUPO7000L supports synchronized stacking via rear-panel reference clock and trigger connections. Multiple units operate as a single capture system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eWhat probes are included?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eEach model ships with passive probes matched to its bandwidth. Differential, current, and high-voltage probes are available separately for specialized measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eCan I upgrade bandwidth after purchase?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eUPO7000L supports a 1 GHz to 2 GHz bandwidth upgrade option. UPO6000LP bandwidth is fixed at purchase — choose the right model up front.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bg-faq\"\u003e\n\u003cp\u003e\u003cb\u003eWhat's covered under the 5-year warranty?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eParts, labor, and return shipping for the full term. 3 years standard plus 2 additional years included on every unit — no registration or extended-warranty purchase required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"text-align:center;margin-top:40px;color:#666;font-style:italic\"\u003e\u003cstrong\u003eRack-mount precision and rack-mount bandwidth — pick the engine that fits your system.\u003c\/strong\u003e\u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/collections\/UPO6000LP_2_sq.jpg?v=1779458657","url":"https:\/\/uni-trendus.com\/collections\/upo6000lp.oembed","provider":"Uni-Trend US","version":"1.0","type":"link"}