{"title":"UPO1000 Options","description":"","products":[{"product_id":"mso-upo1000x-1mt2m","title":"MSO\/UPO1000X-1MT2M 200MHz BW Upgrade for MSO\/UPO1104","description":"\u003ch1\u003eMSO\/UPO1000X-1MT2M 200MHz BW Upgrade for MSO\/UPO1104\u003c\/h1\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe MSO\/UPO1000X-1MT2M upgrades your MSO\/UPO1104 from 100MHz to 200MHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 200MHz.\u003c\/p\u003e\n\u003cp\u003eA 100MHz oscilloscope faithfully reproduces signals up to roughly 100MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 200MHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz → 200MHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your MSO\/UPO1104.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 200MHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 100MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 200MHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the MSO\/UPO1104 (100MHz). Not needed if your instrument already has 200MHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the MSO\/UPO1104 (100MHz). If your instrument already has 200MHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":46792290337052,"sku":"191502400001","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO-UPO1000X-1MT2M.png?v=1723075558"},{"product_id":"upo1000cs-auto","title":"UPO1000CS-AUTO Auto serial bus trigger and analysis (CAN, LIN)","description":"\u003ch1\u003eUPO1000CS-AUTO Auto serial bus trigger and analysis (CAN, LIN)\u003c\/h1\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe UPO1000CS-AUTO adds CAN and LIN automotive bus triggering, decoding, and search to your \u003ca href=\"\/collections\/upo1000cs\"\u003eUPO1000CS Series\u003c\/a\u003e oscilloscope in a single license — the two most common vehicle network protocols.\u003c\/p\u003e\n\u003cp\u003eCAN handles powertrain, body control, and diagnostics (OBD-II). LIN handles comfort and convenience systems (windows, mirrors, seats, lighting). Together they cover the bus protocols found in the majority of automotive electronics projects.\u003c\/p\u003e\n\u003cp\u003eBuying the bundle costs less than purchasing the included options separately, and it keeps the bench ready when a new requirement turns up mid-project. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN Protocol Decode\u003c\/strong\u003e — Trigger on frame ID, data, error frames. Decoded frames overlay the analog waveform for signal-protocol correlation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLIN Protocol Decode\u003c\/strong\u003e — Trigger on frame IDs, data, checksum errors. Master-slave timing visible alongside electrical signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Protocols, One License\u003c\/strong\u003e — CAN and LIN activated together at a bundled price.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Memory Search\u003c\/strong\u003e — Search captured records for specific messages or errors across the full acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVehicle Network Debug\u003c\/strong\u003e — Your project uses both CAN (ECU communication) and LIN (body electronics). One license covers both bus types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive Training\u003c\/strong\u003e — Teaching automotive electronics? CAN and LIN are the two buses every automotive engineer encounters first.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all \u003ca href=\"\/collections\/upo1000cs\"\u003eUPO1000CS Series\u003c\/a\u003e oscilloscopes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes this include CAN-FD?\u003c\/h3\u003e\n\u003cp\u003eNo. This bundle includes classic CAN and LIN only. CAN-FD is available on higher-tier oscilloscope series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":46897773379868,"sku":"191501400001","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO1000CS-AUTO.png?v=1712777008"},{"product_id":"upo1002x-1mt2m","title":"UPO1002X-1MT2M 200MHz Bandwidth Upgrade","description":"\u003ch1\u003eUPO1002X-1MT2M 200MHz Bandwidth Upgrade\u003c\/h1\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe UPO1002X-1MT2M upgrades your UPO1102 from 100MHz to 200MHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 200MHz.\u003c\/p\u003e\n\u003cp\u003eA 100MHz oscilloscope faithfully reproduces signals up to roughly 100MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 200MHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz → 200MHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your UPO1102.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 200MHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 100MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 200MHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the UPO1102 (100MHz). Not needed if your instrument already has 200MHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the UPO1102 (100MHz). If your instrument already has 200MHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":49590748512540,"sku":"191502400010","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UPO1002X-1MT2M.png?v=1723078215"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/collections\/UPO1000_Options.jpg?v=1774903362","url":"https:\/\/uni-trendus.com\/collections\/upo1000-options.oembed","provider":"Uni-Trend US","version":"1.0","type":"link"}