{"title":"MSO8804HD Options","description":"\u003cp\u003eExtend your UNI-T MSO8804HD oscilloscope with these options.\u003c\/p\u003e","products":[{"product_id":"mso8000hd-8b10b","title":"MSO8000HD-8B10B 8b\/10b Signal Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-8B10B decodes 8b\/10b encoded data streams used in PCIe Gen 1\/2, SATA, Fibre Channel, and other high-speed serial interfaces. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8b\/10b Decoding\u003c\/strong\u003e — Decodes K-characters, data symbols, and running disparity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriggering\u003c\/strong\u003e — Trigger on specific symbols, control characters, or disparity errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies encoding violations and disparity errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe Debug\u003c\/strong\u003e — Verify link training sequences and decode TLP\/DLLP packets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSATA Analysis\u003c\/strong\u003e — Decode SATA link layer traffic for storage interface debug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850605162780,"sku":"191500800003","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-8B10B.png?v=1758660846"},{"product_id":"mso8000hd-aero","title":"MSO8000HD-AERO Aerospace Serial Bus Trigger Package Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-AERO adds both MIL-STD-1553 and ARINC 429 aerospace bus decode to your MSO8000HD Series oscilloscope in a single license — the two primary avionics data buses for military and commercial aircraft.\u003c\/p\u003e\n\u003cp\u003eMIL-STD-1553 (military, 1 Mbit\/s, redundant) and ARINC 429 (commercial, 100\/12.5 kbit\/s, unidirectional). Combined license at lower cost than purchasing separately. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIL-STD-1553 Decode\u003c\/strong\u003e — Trigger and decode command words, status words, data words, RT addresses, errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARINC 429 Decode\u003c\/strong\u003e — Trigger and decode 32-bit words with label, SDI, data, SSM, parity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombined License\u003c\/strong\u003e — Both protocols in a single key — no separate purchases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Manchester violations, sync errors, parity failures, and timing violations for both.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvionics Lab\u003c\/strong\u003e — Your bench handles both military (1553) and commercial (ARINC 429) hardware — one license covers both.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlight Data Recorder\u003c\/strong\u003e — Recorder accepts data over both buses. Decode and verify incoming data from both bus types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need Aerospace, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850605392156,"sku":"191502800007","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-AERO.png?v=1758660860"},{"product_id":"mso8000hd-audio","title":"MSO8000HD-AUDIO Audio Serial Bus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-AUDIO adds audio serial bus triggering, decoding, and search for I2S, Left-Justified, Right-Justified, and TDM protocols to your MSO8000HD Series oscilloscope — the standard digital audio interfaces between DACs, ADCs, codecs, and DSPs.\u003c\/p\u003e\n\u003cp\u003eDesigning audio hardware and tracking down clicks, pops, or dropouts? This option shows decoded audio sample values overlaid on clock and data waveforms. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Format Support\u003c\/strong\u003e — Decodes I2S, LJ, RJ, and TDM. Configurable word size (16\/24\/32-bit) and channel count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample-Level Triggering\u003c\/strong\u003e — Trigger on specific audio sample values or ranges — capture clipping, silence, or test tones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Decoding\u003c\/strong\u003e — Decoded samples display aligned with BCLK, LRCLK\/WS, and data for timing verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Identification\u003c\/strong\u003e — Labels left\/right channels or TDM time slots for multi-channel debugging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDAC Interface Verification\u003c\/strong\u003e — Decode I2S data to verify sample values and check BCLK\/LRCLK timing for data latching issues causing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfotainment Debug\u003c\/strong\u003e — An amplifier clicks during source switching. Trigger on the TDM stream to identify invalid samples, clock glitches, or muting logic issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need Audio (I2S\/LJ\/RJ\/TDM), the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850605621532,"sku":"191502700006","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-AUDIO.png?v=1758660869"},{"product_id":"mso8000hd-awg","title":"MSO8000HD-AWG Arbitrary Waveform Generator Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-AWG adds a built-in arbitrary waveform generator and Bode plot analysis. Generate stimulus signals and capture responses on the same instrument — no external function generator needed.\u003c\/p\u003e\n\u003cp\u003eThe Bode plot function sweeps a stimulus across frequencies, measures gain and phase, and plots the diagram on screen. The fastest way to characterize filters, amplifiers, and feedback loops. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e — Independent output channels with sine, square, ramp, pulse, noise, DC, and arbitrary waveforms. No external generator needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e — Automated frequency response — define start\/stop frequency and stimulus amplitude, get gain and phase plots. Essential for filter, amplifier, and loop stability verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStimulus-Response\u003c\/strong\u003e — Generate and capture on the same instrument. No sync issues or ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArbitrary Waveforms\u003c\/strong\u003e — Load custom shapes for specialized testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Stability\u003c\/strong\u003e — Verify DC-DC converter feedback loop phase margin. Sweep 10 Hz to the AWG limit and read gain\/phase margin directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Characterization\u003c\/strong\u003e — Verify cutoff, roll-off, and passband flatness against simulation automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a standalone generator replacement?\u003c\/h3\u003e\n\u003cp\u003eThe built-in AWG handles common stimulus-response tasks. For higher amplitude, better fidelity, and complex modulation, a dedicated waveform generator is recommended.\u003c\/p\u003e\n\u003ch3\u003eIs Bode plot included with AWG?\u003c\/h3\u003e\n\u003cp\u003eYes. Bode plot uses the AWG outputs as stimulus, so the AWG license is required. Bode plot is included at no extra cost.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850606309660,"sku":"191502600006","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-AWG.png?v=1758660878"},{"product_id":"mso8000hd-bnd","title":"MSO8000HD-BND Protocol Analysis and Jitter Suite","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-BND unlocks the entire library of serial bus analysis options for your MSO8000HD Series oscilloscope in a single license — automotive (CAN-FD, FlexRay, SENT, PSI5), audio (Audio (I2S\/LJ\/RJ\/TDM)), aerospace (Aerospace), other (JITTER), wireless\/industrial (Manchester), embedded (I3C, SMBus), embedded\/mobile (SPMI). One key, every protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e The bundle costs less than buying the included options separately.\u003c\/strong\u003e Future-proof your bench and eliminate procurement delays. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's Included\u003c\/strong\u003e — 11 protocols with full trigger, decode, and search:\n\u003cul\u003e\n\u003cli\u003e\nCAN-FD\n\u003c\/li\u003e\n\u003cli\u003e\nFlexRay\n\u003c\/li\u003e\n\u003cli\u003e\nSENT (SAE J2716)\n\u003c\/li\u003e\n\u003cli\u003e\nAudio Serial Bus (I2S, LJ, RJ, TDM)\n\u003c\/li\u003e\n\u003cli\u003e\nAerospace Bus (MIL-STD-1553 + ARINC 429)\n\u003c\/li\u003e\n\u003cli\u003e\nJITTER\n\u003c\/li\u003e\n\u003cli\u003e\nPSI5 (Peripheral Sensor Interface 5)\n\u003c\/li\u003e\n\u003cli\u003e\nManchester Encoding\n\u003c\/li\u003e\n\u003cli\u003e\nI3C (MIPI I3C)\n\u003c\/li\u003e\n\u003cli\u003e\nSMBus\n\u003c\/li\u003e\n\u003cli\u003e\nSPMI\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle savings\u003c\/strong\u003e — One bundle price covers every included option for considerably less than buying them separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle License Key\u003c\/strong\u003e — One key unlocks all protocols. No managing separate licenses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Proof\u003c\/strong\u003e — Every protocol ready when you need it. No procurement delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Domain Development\u003c\/strong\u003e — Your product uses multiple bus types. The BND covers everything from day one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Lab Ready for Anything\u003c\/strong\u003e — Serves clients across automotive, aerospace, and consumer electronics. Every protocol available without scrambling for licenses mid-project.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO\/UPO2000, MSO\/UPO3000CS, MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eI only need two protocols. Is the bundle worth it?\u003c\/h3\u003e\n\u003cp\u003eCompare the combined individual price to the bundle price. The bundle often wins at just two or three protocols — and future projects may need more.\u003c\/p\u003e\n\u003ch3\u003eDoes BND include power analysis, AWG, or bandwidth upgrades?\u003c\/h3\u003e\n\u003cp\u003eNo. BND covers serial bus protocols only. MSO8000HD-AWG Arbitrary Waveform Generator Option, MSO8000HD-LA 16-Channel Logic Analyzer Option, MSO8000HD-PWR Advanced power analysis for MSO8504HD are separate options.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850606735644,"sku":"191502900003","price":5399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-BND.png?v=1758660888"},{"product_id":"mso8000hd-canfd","title":"MSO8000HD-CANFD Automotive CAN-FD Serial Bus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-CANFD adds CAN-FD (Controller Area Network with Flexible Data Rate) protocol triggering, decoding, and search to your MSO8000HD Series oscilloscope. Decoded CAN-FD frames appear overlaid on the analog waveform — protocol data and electrical signals visible simultaneously.\u003c\/p\u003e\n\u003cp\u003eCAN-FD supports payloads up to 64 bytes at up to 8 Mbit\/s. Standard in vehicles from 2020 onward, this decode also handles classic CAN frames on the same bus. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol-Aware Triggering\u003c\/strong\u003e — Trigger on CAN-FD conditions — frame ID, data, error frames, or bit rate switch events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Frame Decoding\u003c\/strong\u003e — Decoded CAN-FD frames (ID, DLC, data, CRC, ACK) display on the waveform for protocol-electrical correlation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Memory Search\u003c\/strong\u003e — Search captured records for specific message IDs, data patterns, or errors across the full memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies CRC, form, stuff, and acknowledge errors for intermittent failure diagnosis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eECU Development\u003c\/strong\u003e — Trigger on your ECU's ID to capture CAN-FD messages and verify timing, payload, and acknowledge behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent Bus Errors\u003c\/strong\u003e — Error frame triggering captures the exact moment a CAN-FD error occurs — examine the waveform to find electrical vs. protocol root causes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need this if I already have classic CAN?\u003c\/h3\u003e\n\u003cp\u003eYes. CAN and CAN-FD are separate protocols. CAN-FD decode also handles classic CAN frames on the same bus.\u003c\/p\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need CAN-FD, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850606965020,"sku":"191501400040","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-CANFD.png?v=1758660900"},{"product_id":"mso8000hd-cts100","title":"MSO8000HD-CTS100 100MBASE-Tx Ethernet Compliance Test Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-CTS100 adds automated 100BASE-Tx Ethernet compliance testing against IEEE 802.3 physical layer specifications — template test, jitter, rise\/fall time, and signal amplitude. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEEE 802.3 Compliance\u003c\/strong\u003e — Automated measurements per 100BASE-Tx physical layer specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemplate (Mask) Test\u003c\/strong\u003e — Pass\/fail testing against the standard eye mask.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Quality Metrics\u003c\/strong\u003e — Jitter, rise\/fall time, amplitude, and symmetry measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePHY Validation\u003c\/strong\u003e — Verify your 100BASE-Tx Ethernet PHY meets IEEE 802.3 specs before compliance testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduction Test\u003c\/strong\u003e — Automated pass\/fail screening for Ethernet port quality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850607194396,"sku":"191503500008","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-CTS100.png?v=1758660911"},{"product_id":"mso8000hd-ctsusb20","title":"MSO8000HD-CTSUSB20 USB 2.0 Compliance Test Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-CTSUSB20 adds automated USB 2.0 compliance testing — signal quality, eye diagram, rise\/fall time, and impedance per USB 2.0 electrical specifications. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB 2.0 Compliance\u003c\/strong\u003e — Automated measurements per USB 2.0 electrical specs for HS (480 Mbps) and FS (12 Mbps).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEye Diagram\u003c\/strong\u003e — Pass\/fail testing against USB 2.0 eye mask templates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Quality\u003c\/strong\u003e — Rise\/fall time, amplitude, and impedance measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePHY Validation\u003c\/strong\u003e — Verify USB 2.0 PHY meets electrical specs for High Speed and Full Speed modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDebug\u003c\/strong\u003e — Identify signal integrity issues causing USB enumeration failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850607391004,"sku":"191503500011","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-CTSUSB20.png?v=1758660920"},{"product_id":"mso8000hd-filter","title":"MSO8000HD-FILTER Advanced Filter Designer Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-FILTER adds a digital filter designer — apply custom FIR and IIR filters to captured waveforms for signal extraction and noise rejection.\u003c\/p\u003e\n\u003cp\u003eWhen standard bandwidth limiting isn't enough — extract specific frequency components or reject known noise sources with full filter control. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Filter Design\u003c\/strong\u003e — Low-pass, high-pass, band-pass, band-stop with configurable cutoff and order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Filtering\u003c\/strong\u003e — Apply to live acquisitions alongside the unfiltered signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIR and IIR\u003c\/strong\u003e — Choose linear phase (FIR) or sharper rolloff (IIR) topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Display\u003c\/strong\u003e — View filter frequency response before applying.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal from Noise\u003c\/strong\u003e — Sensor signal buried in switching noise. Design a low-pass filter to reveal it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Isolation\u003c\/strong\u003e — Extract a specific frequency component for amplitude\/phase analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850607718684,"sku":"191503000002","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-FILTER.png?v=1758660931"},{"product_id":"mso8000hd-flex","title":"MSO8000HD-FLEX Automotive FlexRay Serial Bus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-FLEX adds FlexRay protocol triggering, decoding, and search to your MSO8000HD Series oscilloscope. FlexRay is a deterministic, fault-tolerant bus for safety-critical chassis control, braking, and drive-by-wire applications.\u003c\/p\u003e\n\u003cp\u003eFlexRay provides dual-channel redundancy and guaranteed time slots for critical messages. This option overlays decoded protocol content on the physical signal for debugging timing and electrical issues simultaneously. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexRay Triggering\u003c\/strong\u003e — Trigger on frame ID, cycle count, payload data, indicator bits, null frames, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Frame Decoding\u003c\/strong\u003e — Decoded frames display with ID, payload, header CRC, and cycle info alongside the analog signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic\/Dynamic Segment Visibility\u003c\/strong\u003e — Identifies static vs. dynamic segment frames for schedule table verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Memory Search\u003c\/strong\u003e — Search acquisitions for specific frame IDs, data patterns, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Control Debug\u003c\/strong\u003e — Verify FlexRay timing in electronic suspension — trigger on static slots and check both protocol timing and signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Validation\u003c\/strong\u003e — Capture both Channel A and B to verify redundant message consistency and failover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need FlexRay, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850607980828,"sku":"191501400039","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-FLEX.png?v=1758660941"},{"product_id":"mso8000hd-i3c","title":"MSO8000HD-I3C Embedded I3C Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-I3C adds I3C (MIPI I3C) protocol triggering, decoding, and search to your MSO8000HD Series oscilloscope — the next-gen sensor bus replacing I2C with speeds up to 12.5 MHz, in-band interrupts, and dynamic addressing on two wires.\u003c\/p\u003e\n\u003cp\u003eEmerging in mobile, IoT, and automotive sensors where I2C is too slow and SPI uses too many pins. Essential decode for I3C bring-up and validation. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI3C Triggering\u003c\/strong\u003e — Trigger on dynamic address assignment, in-band interrupts, CCCs, and private transfers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Decoding\u003c\/strong\u003e — Decoded I3C transactions — addresses, CCCs, payload, ACK\/T-bit status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI2C Backward Compatibility\u003c\/strong\u003e — Identifies and decodes legacy I2C devices sharing the bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-Band Interrupt Visibility\u003c\/strong\u003e — Shows IBI events and arbitration between devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Hub Bring-Up\u003c\/strong\u003e — Multiple I3C sensors on one bus. Decode dynamic address assignment to verify unique addresses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI2C-to-I3C Migration\u003c\/strong\u003e — Mixed bus with legacy I2C and new I3C sensors. Verify mixed-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO5000HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need I3C, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850608177436,"sku":"191501400041","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-I3C.png?v=1758660951"},{"product_id":"mso8000hd-jitter","title":"MSO8000HD-JITTER Advanced Jitter Analysis and Eye Diagram Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-JITTER adds advanced jitter analysis and eye diagram measurements for signal integrity assessment in high-speed serial links and clock systems.\u003c\/p\u003e\n\u003cp\u003eFor PCIe, USB, HDMI, DDR, or custom serial links — decompose timing variations and verify receiver requirements with eye diagrams. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJitter Decomposition\u003c\/strong\u003e — Separates RJ, DJ, PJ, DDJ, and DCD for root-cause analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEye Diagram\u003c\/strong\u003e — Statistical eye from serial data for signal quality — eye height, width, mask margin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBathtub Curve\u003c\/strong\u003e — BER vs. sampling position for link margin prediction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Jitter\u003c\/strong\u003e — Period jitter, cycle-to-cycle, and TIE for clock characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Link Validation\u003c\/strong\u003e — Intermittent bit errors. Generate eye diagram for quality assessment, decompose jitter to find the source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Characterization\u003c\/strong\u003e — Measure period\/cycle-to-cycle jitter on an oscillator for PLL and data converter requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850608800028,"sku":"191501100003","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-JITTER.png?v=1758660964"},{"product_id":"mso8000hd-la","title":"MSO8000HD-LA 16-Channel Logic Analyzer Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-LA enables 16 digital channels for mixed-signal analysis — digital bus states time-aligned with analog waveforms. Requires UT-M15 or UT-M26 logic probe pod (sold separately).\u003c\/p\u003e\n\u003cp\u003eSee analog signals and digital bus states on the same time base. Essential for microprocessor, FPGA, and parallel bus debugging. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels\u003c\/strong\u003e — Parallel bus capture alongside analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-Aligned Display\u003c\/strong\u003e — Digital and analog share the same time base for comprehensive debugging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Correlation\u003c\/strong\u003e — Digital bus activity alongside serial decodes and analog measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequires Probe Pod\u003c\/strong\u003e — UT-M15 or UT-M26 connects to the digital input port. License enables the channels; probe captures signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor Debug\u003c\/strong\u003e — Capture address\/data bus on digital channels while probing power and clocks on analog.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFPGA Interface\u003c\/strong\u003e — Verify parallel data bus timing between FPGA and peripherals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO7000X.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need the probe pod separately?\u003c\/h3\u003e\n\u003cp\u003eYes. The LA license enables 16 digital channels in software. The UT-M15 or UT-M26 probe pod (sold separately) provides the physical connections.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850608996636,"sku":"191501300004","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-LA.png?v=1758660977"},{"product_id":"mso8000hd-manch","title":"MSO8000HD-MANCH Serial Bus Manchester Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-MANCH adds Manchester encoding trigger and decode to your MSO8000HD Series oscilloscope — a self-clocking line code used in 10BASE-T Ethernet, RFID, NFC, and industrial protocols.\u003c\/p\u003e\n\u003cp\u003eDecodes data content directly on screen, saving manual transition interpretation. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManchester Decode\u003c\/strong\u003e — Decodes Manchester and Differential Manchester data with bit values on the waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Parameters\u003c\/strong\u003e — Set bit rate, idle polarity, and convention (IEEE 802.3 or G.E. Thomas).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePattern Triggering\u003c\/strong\u003e — Trigger on specific data patterns in the encoded stream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies encoding violations at mid-bit boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFID Debug\u003c\/strong\u003e — Decode reader-to-tag and tag-to-reader Manchester communication for command\/response verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Sensor\u003c\/strong\u003e — Custom sensor uses Manchester encoding. Decode to verify data content and timing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO3000HD, MSO3000X, MSO5000HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need Manchester, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850609226012,"sku":"191500800002","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-MANCH.png?v=1758660986"},{"product_id":"mso8000hd-mat","title":"MSO8000HD-MAT MATLAB Embedded Programming Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-MAT adds MATLAB embedded programming — run MATLAB scripts directly on the oscilloscope for custom analysis and automation without data transfer.\u003c\/p\u003e\n\u003cp\u003eIf your workflow relies on MATLAB for custom signal processing or automated test sequences, this runs those scripts on the instrument. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Instrument MATLAB\u003c\/strong\u003e — Run scripts directly without PC data transfer overhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument Data Access\u003c\/strong\u003e — Scripts access waveform data, measurements, and settings directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Analysis\u003c\/strong\u003e — Proprietary algorithms, custom measurements, automated sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo PC Required\u003c\/strong\u003e — Execute analysis workflows without connecting to a computer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Processing\u003c\/strong\u003e — Run proprietary demodulation on captured RF signals directly on the scope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Testing\u003c\/strong\u003e — MATLAB script configures, captures, analyzes, and logs results automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need a MATLAB license?\u003c\/h3\u003e\n\u003cp\u003eYes. A valid MathWorks MATLAB license is required — the MATLAB runtime is not included.\u003c\/p\u003e\n\u003ch3\u003eWhere do MATLAB scripts run?\u003c\/h3\u003e\n\u003cp\u003eDirectly on the instrument, with no PC round-trip.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850609422620,"sku":"191503400002","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-MAT.png?v=1758660995"},{"product_id":"mso8000hd-md2g","title":"MSO8000HD-MD2G Double the MSO8000HD Memory to 2Gpts","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-MD2G doubles acquisition memory from 1 Gpts to 2 Gpts — longer captures at full sample rate or higher resolution for the same duration.\u003c\/p\u003e\n\u003cp\u003eMemory depth determines capture length at a given sample rate. Doubling means twice as long at full speed — essential for infrequent events and long protocol sequences. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Gpts Memory\u003c\/strong\u003e — Doubles standard 1 Gpt across all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger Full-Speed Captures\u003c\/strong\u003e — Twice the duration at maximum sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Protocol Search\u003c\/strong\u003e — Search longer captures for intermittent errors over extended periods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRare Event Capture\u003c\/strong\u003e — A glitch occurs every few seconds. Capture a longer window at full rate to catch it without missing details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Protocol Sequences\u003c\/strong\u003e — Debug a boot sequence taking several seconds with full decode across the entire capture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850609619228,"sku":"191503300001","price":5399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-MD2G.png?v=1758661002"},{"product_id":"mso8000hd-net","title":"MSO8000HD-NET 10BASE-T, 100BASE-TX Ethernet Bus Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-NET adds 10BASE-T and 100BASE-TX Ethernet bus triggering, decoding, and search for protocol-level frame analysis. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Frame Decode\u003c\/strong\u003e — Trigger and decode Ethernet frames including preamble, MAC addresses, type\/length, data, and FCS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies FCS errors, runt frames, and jabber conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriggering\u003c\/strong\u003e — Trigger on MAC addresses, frame types, or specific data patterns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet\u003c\/strong\u003e — Debug Ethernet communication in industrial or embedded systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Troubleshooting\u003c\/strong\u003e — Capture and decode Ethernet frames to diagnose communication failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850609848604,"sku":"191503200001","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-NET.png?v=1758661010"},{"product_id":"mso8000hd-nrz","title":"MSO8000HD-NRZ NRZ Signal Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-NRZ adds NRZ (Non-Return-to-Zero) signal decode and analysis — the foundation encoding for many high-speed serial protocols. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNRZ Decoding\u003c\/strong\u003e — Decode NRZ data streams with configurable bit rate and threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEye Diagram\u003c\/strong\u003e — Generate eye diagrams for NRZ signal quality assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePattern Triggering\u003c\/strong\u003e — Trigger on specific bit patterns in the NRZ stream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Link Debug\u003c\/strong\u003e — Decode NRZ data to verify bit patterns and analyze signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Protocol\u003c\/strong\u003e — Decode proprietary NRZ-based serial links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850610307356,"sku":"191500800001","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-NRZ.png?v=1758661018"},{"product_id":"mso8000hd-pcie2","title":"MSO8000HD-PCIe2 PCIe Bus Trigger and Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-PCIe2 adds PCIe Gen 1\/2 protocol triggering, decoding, and search for PCI Express link training, TLP\/DLLP packets, and data transfers. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe Protocol Decode\u003c\/strong\u003e — Trigger and decode PCIe Gen 1\/2 transactions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLink Training\u003c\/strong\u003e — Capture and decode LTSSM state transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTLP\/DLLP Decode\u003c\/strong\u003e — Transaction and data link layer packet decoding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe Debug\u003c\/strong\u003e — Diagnose link training failures or enumeration issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer Analysis\u003c\/strong\u003e — Decode TLP packets for data transfer verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850610536732,"sku":"191503200003","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-PCIe2.png?v=1758661025"},{"product_id":"mso8000hd-psi5","title":"MSO8000HD-PSI5 Automotive PSI5 Serial Bus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-PSI5 adds PSI5 protocol decode to your MSO8000HD Series oscilloscope — a two-wire automotive sensor interface for airbag crash sensors, occupant detection, and restraint systems.\u003c\/p\u003e\n\u003cp\u003ePSI5 uses current modulation on power supply wires. Decode shows sensor data values and sync frames from the current waveform. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSI5 Decoding\u003c\/strong\u003e — Sensor data frames with sync pulses, data bits, status, and CRC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent-Modulated Support\u003c\/strong\u003e — Interprets data from current waveforms captured through a current probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriggering\u003c\/strong\u003e — Trigger on sensor data values, errors, or sync patterns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — CRC failures, missing sync pulses, timing violations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirbag Sensor Validation\u003c\/strong\u003e — Verify crash sensor PSI5 output: acceleration data, update rates, CRC under simulated crash conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestraint System Integration\u003c\/strong\u003e — Airbag ECU can't read a sensor. Decode PSI5 to find bad data vs. insufficient current modulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need PSI5, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850610733340,"sku":"191501400038","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-PSI5.png?v=1758661033"},{"product_id":"mso8000hd-sent","title":"MSO8000HD-SENT Automotive SENT Serial Bus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-SENT adds SENT (Single Edge Nibble Transmission, SAE J2716) protocol triggering, decoding, and search to your MSO8000HD Series oscilloscope. SENT is a point-to-point sensor interface for automotive throttle, pressure, airflow, and temperature sensors.\u003c\/p\u003e\n\u003cp\u003eSENT transmits digital data on a single wire, immune to analog noise and ground offsets. This decode reads sensor data values directly from the oscilloscope screen. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSENT Triggering\u003c\/strong\u003e — Trigger on fast channel data, slow channel messages, or error conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast and Slow Channel Decoding\u003c\/strong\u003e — Decodes fast channel (primary sensor data) and slow channel (config\/diagnostics).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNibble-Level Display\u003c\/strong\u003e — Individual nibble values and timing overlaid on the waveform for SAE J2716 verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRC Verification\u003c\/strong\u003e — Checks CRC for every message — essential for detecting intermittent failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Validation\u003c\/strong\u003e — Verify SENT-output pressure sensor data accuracy — digital values shown in real time alongside the pulse train.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECU Input Debug\u003c\/strong\u003e — ECU reports erratic throttle readings. Decode SENT to find whether the sensor or ECU is at fault.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need SENT, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850611159324,"sku":"191501400042","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-SENT.png?v=1758661049"},{"product_id":"mso8000hd-smbus","title":"MSO8000HD-SMBUS Embedded Serial Bus SMBus Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-SMBUS adds SMBus (System Management Bus) protocol decode to your MSO8000HD Series oscilloscope — I2C-derived protocol for power management, battery management, temperature monitoring, and fan control.\u003c\/p\u003e\n\u003cp\u003eSMBus adds packet error checking (PEC), host notify, alert response, and specific commands over the I2C layer. Essential for PMIC and battery charger development. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMBus Decoding\u003c\/strong\u003e — Quick Command, Send\/Receive Byte, Read\/Write Word, Block transfers, Process Call.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEC Verification\u003c\/strong\u003e — Validates Packet Error Checking CRC — not available in standard I2C decode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost Notify and Alert\u003c\/strong\u003e — Decodes SMBus alert protocol and host notification events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriggering\u003c\/strong\u003e — Trigger on command types, data values, and PEC errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Management Debug\u003c\/strong\u003e — Smart battery charger communicating with fuel gauge over SMBus. Verify state-of-charge reads and PEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServer BMC Development\u003c\/strong\u003e — BMC reads sensors and controls fans over SMBus. Verify polling intervals and alerts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan I use I2C decode instead?\u003c\/h3\u003e\n\u003cp\u003eI2C shows raw bytes but misses SMBus-specific features (PEC, Quick Commands, Block transfers, Alert Response). If your design uses SMBus features, you need this option.\u003c\/p\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need SMBus, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850611388700,"sku":"191501200032","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-SMBUS.png?v=1758661055"},{"product_id":"mso8000hd-spmi","title":"MSO8000HD-SPMI Power Management Serial Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-SPMI adds SPMI (System Power Management Interface) protocol decode to your MSO8000HD Series oscilloscope — a MIPI protocol for mobile processor-to-PMIC communication.\u003c\/p\u003e\n\u003cp\u003eSPMI controls voltage regulators, battery charging, and power sequencing in mobile devices. Decode reveals register accesses driving the power architecture. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPMI Decoding\u003c\/strong\u003e — Command sequences, register read\/write, master\/slave transactions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriggering\u003c\/strong\u003e — Trigger on slave addresses, register addresses, data values, or command types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Master Support\u003c\/strong\u003e — Identifies transactions from multiple bus masters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Bus contention, parity errors, protocol violations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePMIC Bring-Up\u003c\/strong\u003e — PMIC not configuring correctly. Decode SPMI to verify register writes during power-up sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Sequencing\u003c\/strong\u003e — Intermittent boot failures. Capture SPMI during boot to find which register write fails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need SPMI, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850611585308,"sku":"191500500007","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-SPMI.png?v=1758661060"},{"product_id":"mso8000hd-usb2","title":"MSO8000HD-USB2 USB2.0 Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO8000HD-USB2 adds USB 2.0 bus triggering, decoding, and search — protocol-level analysis of USB transactions (setup, data, status, handshake packets). The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB 2.0 Protocol Decode\u003c\/strong\u003e — Trigger and decode USB 2.0 transactions at the packet level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransaction Visibility\u003c\/strong\u003e — See setup, data, status, and handshake packets decoded on the waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies CRC errors, timeout violations, and protocol errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Debug\u003c\/strong\u003e — Decode USB 2.0 transactions to debug enumeration failures or data transfer errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Analysis\u003c\/strong\u003e — Capture and decode USB traffic between host and device for protocol compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with the MSO8000HD Series: MSO8804HD (8 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52850611781916,"sku":"191503200002","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-USB2.png?v=1758661066"},{"product_id":"mso8000hd-ctsdphy12","title":"MSO8000HD-CTSDPHY12 MIPI D-PHY v1.2 Compliance Test Option","description":null,"brand":"UNI-T","offers":[{"title":"Default Title","offer_id":54580436369692,"sku":"191503500012","price":7399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-CTSDPHY12.png?v=1790006725"},{"product_id":"mso8000hd-cts1000","title":"MSO8000HD-CTS1000 1000 BASE-T Ethernet Compliance Test Option","description":null,"brand":"UNI-T","offers":[{"title":"Default Title","offer_id":54580436435228,"sku":"191503500010","price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/MSO8000HD-CTS1000.png?v=1790006592"}],"url":"https:\/\/uni-trendus.com\/collections\/mso8804hd-options.oembed","provider":"Uni-Trend US","version":"1.0","type":"link"}